Your browser doesn't support javascript.
loading
Histologic evaluation of a catheter coated with paclitaxel PLGA nanoparticles in the internal jugular veins of rats.
Kim, Song-Yi; Aryal, Susmita; Yun, Wan Su; Kim, Woo Cheol; Moon, Suk-Bae; Chae, Gi-Bong; Key, Jaehong; Kim, Seongyup.
Afiliação
  • Kim SY; Department of Surgery, Chungnam National University Sejong Hospital, Sejong, Korea.
  • Aryal S; Department of Biomedical Engineering, Yonsei University, Wonju, Korea.
  • Yun WS; Department of Biomedical Engineering, Yonsei University, Wonju, Korea.
  • Kim WC; Department of Biomedical Engineering, Yonsei University, Wonju, Korea.
  • Moon SB; Department of Surgery, College of Medicine, Kangwon National University, Chun-Cheon, Korea.
  • Chae GB; Department of Surgery, College of Medicine, Kangwon National University, Chun-Cheon, Korea.
  • Key J; Department of Biomedical Engineering, Yonsei University, Wonju, Korea.
  • Kim S; Department of Surgery, College of Medicine, Yonsei University, Wonju, Korea.
Biomed Eng Lett ; 13(3): 505-514, 2023 Aug.
Article em En | MEDLINE | ID: mdl-37519876
ABSTRACT
The aim of this study is to investigate the potential impact of catheterization on intimal hyperplasia and explore the efficacy of Paclitaxel loaded PLGA nanoparticles (PTX-NPs) in preventing stenosis at the site of venous injury. Under general anesthesia, Central Venous Catheters were inserted into the rat's right internal jugular veins (IJV) using the cut-down technique. Twenty bare catheters (C) and twenty PTX-NPs coated catheters (P) were assigned to one of four groups (C2, C4, P2, or P4) based on catheter type and expected survival time. 2 or 4 weeks after surgery, IJVs were completely harvested by formalin fixation and gelatin infusion and slides were stained with H&E (Haematoxylin and Eosin) and Masson's technique. The P2 (Paclitaxel coating, 2 weeks) group showed the most proliferation among the four groups and the P4 (Paclitaxel coating, 4 weeks) showed a tendency to decrease proliferation. Additionally, the lumen size in the P4 group was about 6% smaller than in the P2 group, and there was a lower prevalence of stenotic grade in the P4 group. Our study suggests that PTX-NPs coated catheters may be effective in preventing venous stenosis if the intended usage is prolonged, rather than for a short-term period. Graphical abstract Schematic representation of catheter functionalization and coating of PTX-NPs on Catheter. Supplementary Information The online version contains supplementary material available at 10.1007/s13534-023-00282-y.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Risk_factors_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Risk_factors_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article