Your browser doesn't support javascript.
loading
Diagnostic Performance of Endoscopic Ultrasonography with Water-Filled Balloon Method for Superficial Esophageal Squamous Cell Carcinoma.
Suzuki, Yugo; Nomura, Kosuke; Kikuchi, Daisuke; Iizuka, Toshiro; Koseki, Mako; Kawai, Yusuke; Okamura, Takayuki; Ochiai, Yorinari; Hayasaka, Junnosuke; Mitsunaga, Yutaka; Odagiri, Hiroyuki; Yamashita, Satoshi; Matsui, Akira; Ohashi, Kenichi; Hoteya, Shu.
Afiliação
  • Suzuki Y; Department of Gastroenterology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo, 105-8470, Japan. yugo-suzuki@nms.ac.jp.
  • Nomura K; Department of Gastroenterology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo, 105-8470, Japan.
  • Kikuchi D; Department of Gastroenterology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo, 105-8470, Japan.
  • Iizuka T; Department of Gastroenterology, Tokyo Metropolitan Cancer and infectious Diseases Center Komagome Hospital, Tokyo, Japan.
  • Koseki M; Department of Gastroenterology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo, 105-8470, Japan.
  • Kawai Y; Department of Gastroenterology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo, 105-8470, Japan.
  • Okamura T; Department of Gastroenterology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo, 105-8470, Japan.
  • Ochiai Y; Department of Gastroenterology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo, 105-8470, Japan.
  • Hayasaka J; Department of Gastroenterology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo, 105-8470, Japan.
  • Mitsunaga Y; Department of Gastroenterology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo, 105-8470, Japan.
  • Odagiri H; Department of Gastroenterology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo, 105-8470, Japan.
  • Yamashita S; Department of Gastroenterology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo, 105-8470, Japan.
  • Matsui A; Department of Gastroenterology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo, 105-8470, Japan.
  • Ohashi K; Department of Human Pathology, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan.
  • Hoteya S; Department of Gastroenterology, Toranomon Hospital, 2-2-2 Toranomon, Minato-ku, Tokyo, 105-8470, Japan.
Dig Dis Sci ; 68(10): 3974-3984, 2023 10.
Article em En | MEDLINE | ID: mdl-37540393
ABSTRACT

BACKGROUND:

Endoscopic ultrasonography (EUS) is a commonly used tool for preoperative depth diagnosis of superficial esophageal squamous cell carcinoma (ESCC). Probing EUS using the water-filled balloon method is a simple and safe examination.

AIM:

The aim of this study was to clarify the diagnostic performance of EUS with the water-filled balloon method for superficial ESCC compared to magnifying narrow-band imaging (ME-NBI).

METHODS:

We retrospectively examined 403 lesions in 393 consecutive patients diagnosed with ESCC and evaluated them with ME-NBI and EUS. Clinicopathological findings were collected, and the accuracy of the preoperative diagnosis was compared between ME-NBI and EUS-B. EUS examiners were not blinded to prior ME-NBI results, and EUS results may have been influenced by ME-NBI results.

RESULTS:

The pathological tumor depth of the EP/LPM in 152 lesions, MM/SM1 in 130 lesions, and deep submucosa (SM2/SM3) in 121 lesions was examined. The proportion of total lesions with an accurate diagnosis was significantly higher in EUS than in ME-NBI (67.7% versus 62.0%, P = 0.015). When analyzed by clinical depth diagnosis using ME-NBI, the proportion of lesions with an accurate diagnosis was significantly higher for EUS in MM/SM1 (55.7% versus 46.1%, P = 0.033). The sensitivity was significantly higher in EUS for SM2/SM3 lesions (76.0% versus 54.5%, P < 0.001). The accuracy and specificity of EUS, which differentiate MM/SM1 from EP/LPM or SM2/SM3, were significantly higher than those of ME-NBI. The median endoscopic ultrasonography procedure time was approximately 6.5 min.

CONCLUSIONS:

EUS with the water-filled balloon method is a safe and straightforward method that can be performed on lesions clinically diagnosed as MM/SM1 using ME-NBI. We retrospectively reviewed lesions in patients diagnosed with ESCC and evaluated them using magnifying endoscopy with narrow-band imaging (ME-NBI) and endoscopic ultrasound using the water-filled balloon method (EUS-B). We conclude that EUS-B can increase the diagnostic accuracy.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Esofágicas / Carcinoma de Células Escamosas / Carcinoma de Células Escamosas do Esôfago Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Esofágicas / Carcinoma de Células Escamosas / Carcinoma de Células Escamosas do Esôfago Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article