Your browser doesn't support javascript.
loading
CBCT-Based Dose Monitoring and Adaptive Planning Triggers in Head and Neck PBS Proton Therapy.
Reiners, Keaton; Dagan, Roi; Holtzman, Adam; Bryant, Curtis; Andersson, Sebastian; Nilsson, Rasmus; Hong, Liu; Johnson, Perry; Zhang, Yawei.
Afiliação
  • Reiners K; University of Florida Health Proton Therapy Institute, Jacksonville, FL 32206, USA.
  • Dagan R; Medical Physics Graduate Program, University of Florida College of Medicine, Gainesville, FL 32610, USA.
  • Holtzman A; University of Florida Health Proton Therapy Institute, Jacksonville, FL 32206, USA.
  • Bryant C; Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL 32610, USA.
  • Andersson S; Department of Radiation Oncology, Mayo Clinic, Jacksonville, FL 32224, USA.
  • Nilsson R; University of Florida Health Proton Therapy Institute, Jacksonville, FL 32206, USA.
  • Hong L; Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL 32610, USA.
  • Johnson P; RaySearch Laboratories, SE-103 65 Stockholm, Sweden.
  • Zhang Y; RaySearch Laboratories, SE-103 65 Stockholm, Sweden.
Cancers (Basel) ; 15(15)2023 Jul 30.
Article em En | MEDLINE | ID: mdl-37568697
ABSTRACT

PURPOSE:

To investigate the feasibility of using cone-beam computed tomography (CBCT)-derived synthetic CTs to monitor the daily dose and trigger a plan review for adaptive proton therapy (APT) in head and neck cancer (HNC) patients.

METHODS:

For 84 HNC patients treated with proton pencil-beam scanning (PBS), same-day CBCT and verification CT (vfCT) pairs were retrospectively collected. The ground truth CT (gtCT) was created by deforming the vfCT to the same-day CBCT, and it was then used as a dosimetric baseline and for establishing plan review trigger recommendations. Two different synthetic CT algorithms were tested; the corrected CBCT (corrCBCT) was created using an iterative image correction method and the virtual CT (virtCT) was created by deforming the planning CT to the CBCT, followed by a low-density masking process. Clinical treatment plans were recalculated on the image sets for evaluation.

RESULTS:

Plan review trigger criteria for adaptive therapy were established after closely reviewing the cohort data. Compared to the vfCT, the corrCBCT and virtCT reliably produced dosimetric data more similar to the gtCT. The average discrepancy in D99 for high-risk clinical target volumes (CTV) was 1.1%, 0.7%, and 0.4% and for standard-risk CTVs was 1.8%, 0.5%, and 0.5% for the vfCT, corrCBCT, and virtCT, respectively.

CONCLUSION:

Streamlined APT has been achieved with the proposed plan review criteria and CBCT-based synthetic CT workflow.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline Idioma: En Ano de publicação: 2023 Tipo de documento: Article