Your browser doesn't support javascript.
loading
Identification of low-level impurities in drug prototypes of carbocisteine by means of liquid chromatography-high-resolution mass spectrometry and general unknown comparative screening.
Walther, Rasmus; Kinzig, Martina; Zamponi, Annette; Sörgel, Fritz; Scherf-Clavel, Oliver; Holzgrabe, Ulrike.
Afiliação
  • Walther R; Institute for Pharmacy and Food Chemistry, University of Wuerzburg, Am Hubland, Würzburg 97074, Germany.
  • Kinzig M; Institute for Biomedical and Pharmaceutical Research, Heroldsberg 90562, Germany.
  • Zamponi A; Global Development Center, A. Nattermann & Cie. GmbH - a Sanofi Company, Köln 50829, Germany.
  • Sörgel F; Institute for Biomedical and Pharmaceutical Research, Heroldsberg 90562, Germany.
  • Scherf-Clavel O; Institute for Pharmacy and Food Chemistry, University of Wuerzburg, Am Hubland, Würzburg 97074, Germany. Electronic address: oliver.scherf-clavel@hs-aalen.de.
  • Holzgrabe U; Institute for Pharmacy and Food Chemistry, University of Wuerzburg, Am Hubland, Würzburg 97074, Germany. Electronic address: ulrike.holzgrabe@uni-wuerzburg.de.
J Chromatogr A ; 1706: 464269, 2023 Sep 13.
Article em En | MEDLINE | ID: mdl-37586140
ABSTRACT
High-resolution tandem quadrupole time-of-flight mass analysers enable new automated workflows for untargeted data evaluation of complex samples like drug products. An example of such procedure is the so-called general unknown comparative screening (GUCS), which is used for software-assisted, automated identification of components that are only present in a sample and not in a reference. The GUCS approach has been employed for the first time to detect both degradation products and reaction products in drug products. Two different carbocisteine containing syrup prototypes - one with sucrose and the other with artificial sweeteners - were selected as examples after nine months of storage at 40 °C and 75% relative humidity. The samples were analysed chromatographically using a Coresep SB mixed-mode column and high-resolution MS and MS/MS data were recorded in information dependant acquisition mode on a Sciex X500R quadrupole time-of-flight mass spectrometer. Data analysis was considerably facilitated using the corresponding placebo formulation as reference samples. With the GUCS approach two hitherto unknown degradation products of carbocisteine, i.e. the carbocisteine lactam of the sulfoxides and the disulfide between l-cysteine and thioglycolic acid, were detected at low concentrations in both of the syrup formulations. The presumed structures were confirmed by in silico analysis of the fragment spectra and high-resolution LC-MS experiments with reference substances. Two additional impurities were found in the sucrose-containing sample and identified as the N-glycosides of carbocisteine and its lactam, respectively, using binary mixtures with a 13C-labelled monosaccharide.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Contaminação de Medicamentos / Espectrometria de Massas em Tandem Tipo de estudo: Clinical_trials / Diagnostic_studies / Screening_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article