Your browser doesn't support javascript.
loading
Echocardiographic determination of right ventricular volumes and ejection fraction: Validation of a truncated cone and rhomboid pyramid formula.
Al Ateah, Ghazi; Kirschfink, Annemarie; Frick, Michael; Almalla, Mohammad; Becker, Michael; Cornelissen, Christian; Hoffmann, Rainer; Marx, Nikolaus; Altiok, Ertunc.
Afiliação
  • Al Ateah G; Department of Cardiology, Nephrology and Internal Intensive Care Medicine, Rhein-Maas Klinikum, Wuerselen, Germany.
  • Kirschfink A; Department of Cardiology, Angiology and Intensive Care, University Hospital RWTH Aachen, Aachen, Germany.
  • Frick M; Department of Cardiology, Angiology and Intensive Care, University Hospital RWTH Aachen, Aachen, Germany.
  • Almalla M; Department of Cardiology, Angiology and Intensive Care, University Hospital RWTH Aachen, Aachen, Germany.
  • Becker M; Department of Cardiology, Nephrology and Internal Intensive Care Medicine, Rhein-Maas Klinikum, Wuerselen, Germany.
  • Cornelissen C; Department of Pneumology and Intensive Care, University Hospital RWTH Aachen, Aachen, Germany.
  • Hoffmann R; Department of Cardiology, St. Bonifatius Hospital, Lingen, Germany.
  • Marx N; Department of Cardiology, Angiology and Intensive Care, University Hospital RWTH Aachen, Aachen, Germany.
  • Altiok E; Department of Cardiology, Angiology and Intensive Care, University Hospital RWTH Aachen, Aachen, Germany.
PLoS One ; 18(8): e0290418, 2023.
Article em En | MEDLINE | ID: mdl-37594956
ABSTRACT

BACKGROUND:

Echocardiographic assessment of right ventricular (RV) measurements may be challenging. The aim of this study was to develop a formula for calculation of RV volumes and function based on measurements of linear dimensions by 2-dimensional (2D) transthoracic echocardiography (TTE) in comparison to cardiovascular magnetic resonance (CMR).

METHODS:

129 consecutive patients with standard TTE and RV analysis by CMR were included. A formula based on the geometric assumptions of a truncated cone minus a truncated rhomboid pyramid was developed for calculations of RV end-diastolic volume (EDV) and RV end-systolic volume (ESV) by using the basal diameter of the RV (Dd and Ds) and the baso-apical length (Ld and Ls) in apical 4-chamber TTE views RV EDV = 1.21 * Dd2 * Ld, and RV ESV = 1.21 * Ds2 * Ls.

RESULTS:

Calculations of RV EDV (ΔRV EDV = 10.2±26.4 ml to CMR, r = 0.889), RV ESV (ΔRV ESV = 4.5±18.4 ml to CMR, r = 0.921) and RV EF (ΔRV EF = 0.5±4.0% to CMR, r = 0.905) with the cone-pyramid formula (CPF) highly agreed with CMR. Impaired RV function on CMR (n = 52) was identified with a trend to higher accuracy by CPF than by conventional echocardiographic parameters (tricuspid annular plane systolic excursion (TAPSE) and fractional area change (FAC)).

CONCLUSION:

Calculations of RV volumes and RV function by 2D TTE with the newly developed CPF were in high concordance to measurements by CMR. Accuracy for detection of patients with reduced RV function were higher by the proposed 2D TTE CPF method than by conventional echocardiographic parameters of TAPSE and RV FAC.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Músculos do Dorso / Insuficiência Cardíaca Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Músculos do Dorso / Insuficiência Cardíaca Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article