Your browser doesn't support javascript.
loading
Self-assembled p-n Ag2O@Bi2O2S nanoflower heterojunctions for sensitive photoelectrochemical immunoassay.
Huang, Xue; Lu, Liling; Lin, Qianyun; Wei, Qiaohua; Tang, Dianping.
Afiliação
  • Huang X; Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, PR China.
  • Lu L; Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, PR China.
  • Lin Q; Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, PR China.
  • Wei Q; Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, PR China. Electronic address: qhw76@fzu.edu.cn.
  • Tang D; Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, PR China. Electronic address: dianping.tang@fzu.edu.cn.
Biosens Bioelectron ; 239: 115608, 2023 Nov 01.
Article em En | MEDLINE | ID: mdl-37603986
ABSTRACT
A new photoelectrochemical immunoassay based on self-assembled p-n Ag2O@Bi2O2S nanoflower heterojunction was designed and developed for quantitative monitoring of prostate-specific antigen (PSA) in biological fluids. Primarily, self-assembled p-n Ag2O@Bi2O2S nanoflower heterojunctions were served as the photoactive materials and coated onto the surface of electrodes. Subsequently, the glucose oxidase (GOx) was bound to the detection antibody (mAb2) labeled gold nanoparticles (Au NPs) and then were employed to accomplish a sandwich-like immunoreaction to generate H2O2 on a microplate incubated with monoclonal anti-PSA antibodies. In the presence of PSA, the product (H2O2) was catalyzed by the substrate, which was used as an electron sacrificial agent to improve signal conversion and capture of photogenerated electrons. Under optimum conditions, a wide linear range of 0.01-50 ng mL-1 and a low detection limit of 5.3 pg mL-1 were accomplished with the sensor, exhibiting an excellent photocurrent response. Moreover, the proposed sensor revealed satisfactory reproducibility, high selectivity, and acceptable accuracy for the real sample testing. Importantly, our work provides a novel strategy for high sensitivity detection of disease-associated biomarkers for the early diagnosis of cancers.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Humans / Male Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Humans / Male Idioma: En Ano de publicação: 2023 Tipo de documento: Article