Your browser doesn't support javascript.
loading
Comparison between Gibson-Cooke and Macroduct Methods in the Cystic Fibrosis Neonatal Screening Program and in Subjects Who Are Cystic Fibrosis Screen-Positive with an Inconclusive Diagnosis.
Dolce, Daniela; Fevola, Cristina; Camera, Erica; Orioli, Tommaso; Lucenteforte, Ersilia; Malanima, Marco Andrea; Taccetti, Giovanni; Terlizzi, Vito.
Afiliação
  • Dolce D; Cystic Fibrosis Regional Reference Center, Department of Paediatric Medicine, Meyer Children's Hospital IRCCS, Viale Gaetano Pieraccini 24, 50139 Florence, Italy.
  • Fevola C; Cystic Fibrosis Regional Reference Center, Department of Paediatric Medicine, Meyer Children's Hospital IRCCS, Viale Gaetano Pieraccini 24, 50139 Florence, Italy.
  • Camera E; Cystic Fibrosis Regional Reference Center, Department of Paediatric Medicine, Meyer Children's Hospital IRCCS, Viale Gaetano Pieraccini 24, 50139 Florence, Italy.
  • Orioli T; Cystic Fibrosis Regional Reference Center, Department of Paediatric Medicine, Meyer Children's Hospital IRCCS, Viale Gaetano Pieraccini 24, 50139 Florence, Italy.
  • Lucenteforte E; Unit of Medical Statistics, Department of Clinical and Experimental Medicine, University of Pisa, 56126 Pisa, Italy.
  • Malanima MA; Unit of Medical Statistics, Department of Clinical and Experimental Medicine, University of Pisa, 56126 Pisa, Italy.
  • Taccetti G; Cystic Fibrosis Regional Reference Center, Department of Paediatric Medicine, Meyer Children's Hospital IRCCS, Viale Gaetano Pieraccini 24, 50139 Florence, Italy.
  • Terlizzi V; Cystic Fibrosis Regional Reference Center, Department of Paediatric Medicine, Meyer Children's Hospital IRCCS, Viale Gaetano Pieraccini 24, 50139 Florence, Italy.
Int J Neonatal Screen ; 9(3)2023 Jul 25.
Article em En | MEDLINE | ID: mdl-37606478
ABSTRACT
The sweat test (ST) is the current diagnostic gold standard for cystic fibrosis (CF). Many CF centres have switched from the Gibson-Cooke method to the Macroduct system-based method. We used these methods simultaneously to compare CF screening outcomes. STs using both methods were performed simultaneously between March and December 2022 at CF Centre in Florence. We included newborns who underwent newborn bloodspot screening (NBS), newborns undergoing transfusion immediately after birth, and children with CF screen-positive, inconclusive diagnosis (CFSPID). We assessed 72 subjects (median age 4.4 months; range 0-76.7) 30 (41.7%) NBS-positive, 18 (25.0%) newborns who underwent transfusion, and 24 (33.3%) children with CFSPID. No significant differences were found between valid sample numbers, by patient ages and groups (p = 0.10) and between chloride concentrations (p = 0.13), except for sweat chloride (SC) measured by the Gibson-Cooke and Macroduct methods in CFSPID group (29.0, IQR 20.0-48.0 and 22.5, IQR 15.5-30.8, respectively; p = 0.01). The Macroduct and Gibson-Cooke methods showed substantial agreement with the SC values, except for CFSPID, whose result may depend on the method of sweat collection. In case of invalid values with Macroduct, the test should be repeated with Gibson-Cooke method.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Screening_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article