Your browser doesn't support javascript.
loading
Influence of varying titanium base abutment heights on retention of zirconia restorations: An in vitro study.
Nguyen, Olivia; Lee, Sang J; Lee, Jason D.
Afiliação
  • Nguyen O; Graduate student, Advanced Graduate Education in Prosthodontics, Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Mass.
  • Lee SJ; Associate Professor, Department of Restorative Dentistry and Biomaterial Sciences, Harvard School of Dental Medicine, Boston, Mass.
  • Lee JD; Instructor, Department of Restorative Dentistry and Biomaterial Sciences, Harvard School of Dental Medicine, Boston, Mass. Electronic address: Jason_lee@hsdm.harvard.edu.
J Prosthet Dent ; 130(4): 604.e1-604.e5, 2023 Oct.
Article em En | MEDLINE | ID: mdl-37633730
STATEMENT OF PROBLEM: Implant manufacturers have introduced titanium base (Ti-Base) abutments with increased abutment heights, ostensibly, to increase the retention of the bonded restoration and to improve overall strength. However, evidence regarding the effects of increasing Ti-Base height on improving retention is lacking. PURPOSE: The purpose of this in vitro study was to evaluate the effect of different Ti-Base abutment heights on the retention of zirconia implant-supported crowns. MATERIAL AND METHODS: Thirty Ti-Base abutments of the same diameter and heights of 3.5 mm (n=10), 4.5 mm (n=10), and 5.5 mm (n=10), were used for testing. Zirconia restorations were cemented onto the Ti-Base abutments with a resin cement after treatment with a 10-methacryloyloxydecyl dihydrogen phosphate primer by a single operator using a positioning device. The zirconia-Ti-Base restorations were tightened to an implant analog embedded in an autopolymerizing resin block. The specimens were placed and tested in a universal testing machine for pull-out testing. Retention was measured by recording the force at load drop. Statistical analysis was performed using 1-way analysis of variance with the Tukey method for pairwise comparisons. RESULTS: The abutment height had a significant effect on retention (P=.010). Ti-Base abutments of 4.5 and 5.5 mm had significantly greater retention than Ti-Base abutments of 3.5 mm (P=.020, P=.040, respectively). However, Ti-Base abutments of 4.5 and 5.5 mm in height were statistically similar (P=.890). CONCLUSIONS: An increase in the height of Ti-Base abutments above the standard 3.5 mm height significantly improved the retention of the overlying restoration.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Titânio / Coroas Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Titânio / Coroas Idioma: En Ano de publicação: 2023 Tipo de documento: Article