Your browser doesn't support javascript.
loading
Differences of cerebral oxygen saturation in dialysis patients: a comparison of three principals of near infrared spectroscopy.
Yagi, Yasunori; Kubo, Yasunori; Hoshino, Koji; Okada, Kazufumi; Hotta, Kiyohiko; Shinohara, Nobuo; Morimoto, Yuji.
Afiliação
  • Yagi Y; Department of Anesthesiology, Hokkaido University Hospital, Sapporo, Japan.
  • Kubo Y; Department of Anesthesiology, Hokkaido University Hospital, Sapporo, Japan.
  • Hoshino K; Department of Anesthesiology, Hokkaido University Hospital, Sapporo, Japan.
  • Okada K; Data Science Center, Promotion Unit, Institute of Health Science Innovation for Medical Care, Hokkaido University Hospital, Sapporo, Japan.
  • Hotta K; Department of Renal and Genitourinary Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Japan.
  • Shinohara N; Department of Renal and Genitourinary Surgery, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Sapporo, Japan.
  • Morimoto Y; Department of Anesthesiology and Critical Care Medicine, Faculty of Medicine and Graduate School of Medicine, Hokkaido University, Kita-15, Nishi-7, Kita-ku, Sapporo, 060-8638, Japan. morim2@med.hokudai.ac.jp.
J Anesth ; 37(6): 861-867, 2023 12.
Article em En | MEDLINE | ID: mdl-37646882
ABSTRACT

PURPOSE:

It has been reported that cerebral oxygen saturation (rSO2) measured by near infrared spectroscopy is low in dialysis patients. We compared the rSO2 values of dialysis patients before living donor kidney transplantation and their donors as controls by using three spectroscopes that utilize different principals, the INVOS 5100C (spatially resolved spectroscopy), FORE-SIGHT ELITE (modified Beer-Lambert law) and tNIRS-1 (time-resolved spectroscopy).

METHODS:

Before induction of anesthesia, the sensors of one of the three spectroscopes were placed on the forehead and rSO2 values were recorded followed by the same measurement using the other two spectroscopes. The primary objective was to compare the rSO2 values of the dialysis patients and controls using the three spectroscopes by the unpaired t test. Then we compared the rSO2 values among the spectroscopes in both dialysis patients and controls by one-way ANOVA. Finally, we examined the relations between the rSO2 values and the physiological values by using the Pearson correlation coefficient.

RESULTS:

Fifteen pairs of dialysis patients and controls were studied. With the INVOS 5100 C, the values of the dialysis patients (59.7 ± 9.7% (mean ± standard deviation) were 13% lower than those of the controls (73.3 ± 6.9%) (P < 0.01). With the tNIRS-1, the values were 57.8 ± 4.8% in the dialysis patients and 63.3 ± 3.5% in the controls (P < 0.01). Almost no differences were observed with the FORE-SIGHT ELITE (71.6 ± 4.9% [dialysis patients] vs. 70.8 ± 4.3% [Controls]) (P = 0.62). Among the spectroscopes, the values were significantly different in both dialysis patients and controls. For the INVOS 5100C and tNIRS-1, correlation coefficients between rSO2 values and blood Hb and serum Alb were more than 0.5.

CONCLUSIONS:

The rSO2 values for comparisons between the dialysis patients and the controls were different according to differences of the principles of the near infrared spectroscopes. In the INVOS 5100C and tNIRS-1, rSO2 values may be related to blood Hb and serum Alb.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxigênio / Diálise Renal Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxigênio / Diálise Renal Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article