Your browser doesn't support javascript.
loading
Low Risk of Inappropriate Shock Among Pediatric Patients With an Implantable Cardioverter Defibrillator: A Single Center Experience.
Einbinder, Tom; Machtei, Ayelet; Birk, Einat; Schamroth Pravda, Nili; Frenkel, George; Amir, Gabriel; Fogelman, Rami.
Afiliação
  • Einbinder T; Department of Pediatric Cardiology, Schneider's Children Medical Center, Petach-Tikva, Israel. tomeinbinder@gmail.com.
  • Machtei A; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel. tomeinbinder@gmail.com.
  • Birk E; Department of Pediatric Cardiology, Schneider's Children Medical Center, Petach-Tikva, Israel.
  • Schamroth Pravda N; Department of Pediatric Cardiology, Schneider's Children Medical Center, Petach-Tikva, Israel.
  • Frenkel G; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Amir G; Department of Cardiology, Rabin Medical Center, Petach-Tikva, Israel.
  • Fogelman R; Department of Pediatric Cardiology, Schneider's Children Medical Center, Petach-Tikva, Israel.
Pediatr Cardiol ; 2023 Sep 05.
Article em En | MEDLINE | ID: mdl-37668692
ABSTRACT
Implantable cardioverter-defibrillators (ICD) are increasingly being used among the pediatric population for indications of both primary and secondary prevention. There is limited long-term data on the outcomes of pediatric patients following ICD implantation. The aim of this study was to investigate the characteristics of this population, burden of appropriate and inappropriate shock and complication rate in a large tertiary pediatric medical center. Included were children under the age of 18 years who underwent ICD implantation and had clinical follow up at our center. Data were retrospectively collected between study period 2005-2020. Primary outcome was the incidence of ICD shock appropriate and inappropriate. Secondary outcome was defining our patient population characteristics. Our cohort included 51 patients who underwent ICD implantation. Mean age at implantation was 10.9 ± 4.7 years and average follow-up time was 67 months. Diagnoses of implanted patients were 28 (55%) patients with syndromes with risk for sudden death, cardiomyopathy in 14 patients (27%) and congenital heart disease (CHD) in 9 patients (18%). Forty-two (82%) patients had an ICD implanted for secondary prevention after experiencing a life-threatening arrhythmia and 9 (18%) for primary prevention. An endocardial system was implanted in 39 (76%) patients and an epicardial systems in 12 (24%) patients. A total of 20 (39%) patients received appropriate shocks for ventricular fibrillation(VF). 5 patients received inappropriate shocks, 4 due to sinus tachycardia and 1 due to rapidly conducted atrial fibrillation. Those who received an inappropriate shock had a significantly shorter ICD-programmed VF detection cycle length compared to those who did not receive an inappropriate shock (320 ms versus 270 ms, p = 0.062). This single center study demonstrates a high rate of appropriate ICD shocks (39%) and a low rate of inappropriate ICD shocks. Accurate programming of ICD devices in the pediatric population is paramount to avoid inappropriate ICD shocks.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Etiology_studies / Risk_factors_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Etiology_studies / Risk_factors_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article