A new algorithm for particle weighted subtraction to decrease signals from unwanted components in single particle analysis.
Fernández-Giménez, E; Martínez, M M; Marabini, R; Strelak, D; Sánchez-García, R; Carazo, J M; Sorzano, C O S.
Afiliação
  • Fernández-Giménez E; Centro Nac. Biotecnología (CSIC), c/Darwin, 3, 28049 Cantoblanco, Madrid, Spain; Univ. Autonoma de Madrid, 28049 Cantoblanco, Madrid, Spain.
  • Martínez MM; Centro Nac. Biotecnología (CSIC), c/Darwin, 3, 28049 Cantoblanco, Madrid, Spain.
  • Marabini R; Centro Nac. Biotecnología (CSIC), c/Darwin, 3, 28049 Cantoblanco, Madrid, Spain; Univ. Autonoma de Madrid, 28049 Cantoblanco, Madrid, Spain.
  • Strelak D; Institute of Computer Science, Masaryk University, Botanická 68a, 60200 Brno, Czech Republic.
  • Sánchez-García R; Department of Statistics, University of Oxford, 24-29 St Giles', Oxford OX1 3LB, United Kingdom; Astex Pharmaceuticals, 436 Cambridge Science Park, Cambridge CB4 0QA, UK.
  • Carazo JM; Centro Nac. Biotecnología (CSIC), c/Darwin, 3, 28049 Cantoblanco, Madrid, Spain.
  • Sorzano COS; Centro Nac. Biotecnología (CSIC), c/Darwin, 3, 28049 Cantoblanco, Madrid, Spain. Electronic address: coss@cnb.csic.es.
J Struct Biol ; 215(4): 108024, 2023 12.
Article em En | MEDLINE | ID: mdl-37704013
Single particle analysis (SPA) in cryo-electron microscopy (cryo-EM) is highly used to obtain the near-atomic structure of biological macromolecules. The current methods allow users to produce high-resolution maps from many samples. However, there are still challenging cases that require extra processing to obtain high resolution. This is the case when the macromolecule of the sample is composed of different components and we want to focus just on one of them. For example, if the macromolecule is composed of several flexible subunits and we are interested in a specific one, if it is embedded in a viral capsid environment, or if it has additional components to stabilize it, such as nanodiscs. The signal from these components, which in principle we are not interested in, can be removed from the particles using a projection subtraction method. Currently, there are two projection subtraction methods used in practice and both have some limitations. In fact, after evaluating their results, we consider that the problem is still open to new solutions, as they do not fully remove the signal of the components that are not of interest. Our aim is to develop a new and more precise projection subtraction method, improving the performance of state-of-the-art methods. We tested our algorithm with data from public databases and an in-house data set. In this work, we show that the performance of our algorithm improves the results obtained by others, including the localization of small ligands, such as drugs, whose binding location is unknown a priori.