Your browser doesn't support javascript.
loading
Development and validation of a deep eutectic solvent-assisted liquid-liquid extraction method for simultaneous quantification of six steroid hormones in serum by liquid chromatography-tandem mass spectrometry.
Li, Jufang; Xu, Aiping; Xue, Jianyou; Qian, Wei; Xu, Ping; Hu, Zhineng; Chen, Chen; Wu, Chaochao.
Afiliação
  • Li J; Zhejiang Biozon Medical Technology Co., Ltd, Hangzhou, Zhejiang 310000, China.
  • Xu A; Laprode (Zhejiang) Analysis Co., Ltd, Hangzhou, Zhejiang 310000, China.
  • Xue J; Zhejiang Biozon Medical Technology Co., Ltd, Hangzhou, Zhejiang 310000, China.
  • Qian W; Zhejiang Biozon Medical Technology Co., Ltd, Hangzhou, Zhejiang 310000, China.
  • Xu P; Zhejiang Biozon Medical Technology Co., Ltd, Hangzhou, Zhejiang 310000, China.
  • Hu Z; Zhejiang Biozon Medical Technology Co., Ltd, Hangzhou, Zhejiang 310000, China.
  • Chen C; Department of Clinical Laboratory, Women's Hospital of Nanjing Medical University, Nanjing Maternity and Child Health Care Hospital, Nanjing, Jiangsu 210004, China. Electronic address: chenchen1986@njmu.edu.cn.
  • Wu C; Zhejiang Biozon Medical Technology Co., Ltd, Hangzhou, Zhejiang 310000, China. Electronic address: wuchaochao@biozon.com.cn.
J Chromatogr A ; 1710: 464413, 2023 Nov 08.
Article em En | MEDLINE | ID: mdl-37806044
ABSTRACT
Steroid hormones have been reported to be associated with endocrine system diseases. This paper proposes a novel procedure of deep eutectic solvent (DES)-assisted liquid-liquid extraction (LLE) to extract six steroid hormones (including cortisone, cortisol, androstenedione, testosterone, 17-hydroxyprogesterone, and progesterone) from serum coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS). A total of five types of L-proline, choline chloride, and citric acid-based DESs were tailored; the DES from L-proline and ethylene glycol at a molar ratio of 14 with 20 % acetonitrile was selected as the best-fit assisted solvent for the six steroid hormones compared with other DESs. The parameters for extraction by selected DES were optimized using Box-Behnken design (BBD), and the optimal extraction conditions are 200 µL of acetonitrile, 100 µL of the sample, and 80 µL of DES. Under optimum conditions, the method has good linear calibration ranges (between 0.07 ng mL-1 and 600 ng mL-1), correlation coefficients of determination (r2>0.99), and low limits of quantification (between 0.02 and 0.60 ng mL-1). The extraction recoveries were in the range of 81.84-114.43 %, and the intra-day and inter-day relative standard deviations (RSDs) were less than 10 %.In general, the DES-LC-MS/MS method is a simple and environmentally-friendly method, which can be complementary to the presently available methods for determining steroid hormones in serum.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem / Solventes Eutéticos Profundos Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas em Tandem / Solventes Eutéticos Profundos Idioma: En Ano de publicação: 2023 Tipo de documento: Article