Your browser doesn't support javascript.
loading
Polymeric nanocomposite electrode for enhanced electrochemical detection of α-lipoic acid: Application in neuroinflammation prevention and clinical analysis.
Lu, Shenyi; Zhang, Ke; Liu, Yu; Zhan, Xiaofeng; Savari, Rojan.
Afiliação
  • Lu S; Department of Rehabilitation Medicine, The Affiliated Hospital of Youjiang Medical University for Nationalities, Baise, 533000, China. Electronic address: drlushenyi@163.com.
  • Zhang K; Department of Bone and Joint Surgery, the First Affiliated Hospital of Guangxi Medical University, Nanning, 530021, China.
  • Liu Y; Guangxi Medical university, Nanning, 530021, China.
  • Zhan X; Guangxi Medical university, Nanning, 530021, China.
  • Savari R; School of Physics, College of Science, University of Tehran, North-Kargar Street, Tehran, 1439955961, Iran.
Environ Res ; 245: 117369, 2024 Mar 15.
Article em En | MEDLINE | ID: mdl-37827372
Using poly (vanillin-co-chitosan)/functionalized MWCNTs/GCE (PV-CS/f-MWCNTs/GCE) as a polymeric nanocomposite modified electrode, the present investigation has been conducted on the electrochemical detection of α-lipoic acid (α-LA) to prevent the activation of microglia inflammation of the nervous system. The manufacture of modified polymeric nanocomposite electrodes was carried out using the established electropolymerization process. Field emission scanning electron microscopy (FE-SEM) and X-ray diffraction (XRD) analyses of structure revealed that the electropolymerization of poly (vanillin-co-chitosan) on the surface of the f-MWCNTs modified electrode was successful. Vanillin-co-chitosan electropolymerization on f-MWCNTs as electroactive sheets can enhance the signal for α-LA electrochemical sensors, according to research on the electrochemical characteristics utilizing cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methodologies. The PV-CS/f-MWCNTs/GCE demonstrated that it had a sensitivity of 0.04664 µA/µM, a detection limit of 0.012 µM, and an excellent response, linear range, and wide linear range to α-LA from 0 to 3000 µM. The results of the application of PV-CS/f-MWCNTs/GCE for determining the concentration of α-LA in a prepared real sample of human serum by DPV and human lipoic acid ELISA Kit analyses via standard addition method illustrated the substantial conformity between the findings of both assays. The results of the DPV analyses resulted in acceptable recovery values (97.60%-99.10%) and appropriate values of the Relative Standard Deviation (RSD) (3.58%-5.07%), which demonstrated the great applicability and accuracy of the results of PV-CS/f-MWCNTs/GCE for determining α-LA concentration in biological fluids and pharmaceutical specimens.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Benzaldeídos / Ácido Tióctico / Quitosana / Nanocompostos Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Benzaldeídos / Ácido Tióctico / Quitosana / Nanocompostos Limite: Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article