Your browser doesn't support javascript.
loading
Non-Invasive Blood Pressure Sensing via Machine Learning.
Attivissimo, Filippo; D'Alessandro, Vito Ivano; De Palma, Luisa; Lanzolla, Anna Maria Lucia; Di Nisio, Attilio.
Afiliação
  • Attivissimo F; Department of Electrical and Information Engineering, Polytechnic University of Bari, 70125 Bari, Italy.
  • D'Alessandro VI; Department of Electrical and Information Engineering, Polytechnic University of Bari, 70125 Bari, Italy.
  • De Palma L; Department of Electrical and Information Engineering, Polytechnic University of Bari, 70125 Bari, Italy.
  • Lanzolla AML; Department of Electrical and Information Engineering, Polytechnic University of Bari, 70125 Bari, Italy.
  • Di Nisio A; Department of Electrical and Information Engineering, Polytechnic University of Bari, 70125 Bari, Italy.
Sensors (Basel) ; 23(19)2023 Oct 09.
Article em En | MEDLINE | ID: mdl-37837172
In this paper, a machine learning (ML) approach to estimate blood pressure (BP) using photoplethysmography (PPG) is presented. The final aim of this paper was to develop ML methods for estimating blood pressure (BP) in a non-invasive way that is suitable in a telemedicine health-care monitoring context. The training of regression models useful for estimating systolic blood pressure (SBP) and diastolic blood pressure (DBP) was conducted using new extracted features from PPG signals processed using the Maximal Overlap Discrete Wavelet Transform (MODWT). As a matter of fact, the interest was on the use of the most significant features obtained by the Minimum Redundancy Maximum Relevance (MRMR) selection algorithm to train eXtreme Gradient Boost (XGBoost) and Neural Network (NN) models. This aim was satisfactorily achieved by also comparing it with works in the literature; in fact, it was found that XGBoost models are more accurate than NN models in both systolic and diastolic blood pressure measurements, obtaining a Root Mean Square Error (RMSE) for SBP and DBP, respectively, of 5.67 mmHg and 3.95 mmHg. For SBP measurement, this result is an improvement compared to that reported in the literature. Furthermore, the trained XGBoost regression model fulfills the requirements of the Association for the Advancement of Medical Instrumentation (AAMI) as well as grade A of the British Hypertension Society (BHS) standard.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Determinação da Pressão Arterial / Hipertensão Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Determinação da Pressão Arterial / Hipertensão Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article