Your browser doesn't support javascript.
loading
Measurement and Simulation of Ultra-Low-Energy Ion-Solid Interaction Dynamics.
Titze, Michael; Poplawsky, Jonathan D; Kretschmer, Silvan; Krasheninnikov, Arkady V; Doyle, Barney L; Bielejec, Edward S; Hobler, Gerhard; Belianinov, Alex.
Afiliação
  • Titze M; Ion Beam Laboratory, Sandia National Laboratories, Albuquerque, NM 87185, USA.
  • Poplawsky JD; Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, TN 37831, USA.
  • Kretschmer S; Institute of Ion Beam Physics and Materials Research, Helmholtz-Zentrum Dresden-Rossendorf, 01328 Dresden, Germany.
  • Krasheninnikov AV; Institute of Ion Beam Physics and Materials Research, Helmholtz-Zentrum Dresden-Rossendorf, 01328 Dresden, Germany.
  • Doyle BL; Ion Beam Laboratory, Sandia National Laboratories, Albuquerque, NM 87185, USA.
  • Bielejec ES; Ion Beam Laboratory, Sandia National Laboratories, Albuquerque, NM 87185, USA.
  • Hobler G; Institute of Solid-State Electronics, TU Wien, Gußhausstraße 25-25a, A-1040 Wien, Austria.
  • Belianinov A; Ion Beam Laboratory, Sandia National Laboratories, Albuquerque, NM 87185, USA.
Micromachines (Basel) ; 14(10)2023 Sep 30.
Article em En | MEDLINE | ID: mdl-37893321
Ion implantation is a key capability for the semiconductor industry. As devices shrink, novel materials enter the manufacturing line, and quantum technologies transition to being more mainstream. Traditional implantation methods fall short in terms of energy, ion species, and positional precision. Here, we demonstrate 1 keV focused ion beam Au implantation into Si and validate the results via atom probe tomography. We show the Au implant depth at 1 keV is 0.8 nm and that identical results for low-energy ion implants can be achieved by either lowering the column voltage or decelerating ions using bias while maintaining a sub-micron beam focus. We compare our experimental results to static calculations using SRIM and dynamic calculations using binary collision approximation codes TRIDYN and IMSIL. A large discrepancy between the static and dynamic simulation is found, which is due to lattice enrichment with high-stopping-power Au and surface sputtering. Additionally, we demonstrate how model details are particularly important to the simulation of these low-energy heavy-ion implantations. Finally, we discuss how our results pave a way towards much lower implantation energies while maintaining high spatial resolution.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article