Your browser doesn't support javascript.
loading
Real-time loop-mediated isothermal amplification for the detection of Giardia duodenalis in fecal specimens.
Khurana, Sumeeta; Sharma, Chayan; Guleria, Sucheta; Mewara, Abhishek; Dutta, Usha.
Afiliação
  • Khurana S; Department of Medical Parasitology, Post Graduate Institute of Medical Education &Research, Chandigarh, India. Electronic address: khuranasumeeta@gmail.com.
  • Sharma C; Department of Medical Parasitology, Post Graduate Institute of Medical Education &Research, Chandigarh, India. Electronic address: chayansharma_1993@yahaoo.com.
  • Guleria S; Department of Medical Parasitology, Post Graduate Institute of Medical Education &Research, Chandigarh, India. Electronic address: sucheta7958@gmail.com.
  • Mewara A; Department of Medical Parasitology, Post Graduate Institute of Medical Education &Research, Chandigarh, India. Electronic address: abhimewara@yahoo.com.
  • Dutta U; Department of Gastroenterology, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India. Electronic address: ushadutta@gmail.com.
Indian J Med Microbiol ; 47: 100492, 2024.
Article em En | MEDLINE | ID: mdl-37918212
INTRODUCTION: Giardiasis is a leading cause of subacute or chronic diarrhoea and is frequently associated with impaired physical, cognitive and psychosocial development, especially in children. The diagnosis relies mainly on the microscopic evaluation of stool specimens that have a low sensitivity. In contrast, molecular advancements like the polymerase chain reaction and Real-time loop-mediated isothermal amplification (Real-time LAMP) are promising techniques and reportedly have better diagnostic characteristics. METHODS: We have evaluated the performance of Real-time LAMP for detecting Giardia in ninety stool specimens compared to microscopy and nested PCR. RESULTS: A total of 35 fecal samples were detected positive by microscopy, 41 by nested PCR and 43 by real-time LAMP. Microscopy and nested PCR detected 33, microscopy and real-time LAMP detected 35, and nested PCR and real-time LAMP detected 41 positive samples. CONCLUSION: The real-time LAMP assay was found suitable for the rapid and accurate detection of G. duodenalis with a better sensitivity in comparison to nested PCR and microscopy. Furthermore, besides being sensitive and rapid, LAMP had the advantage of an adequate rapid turn-around time of eleven to 15 â€‹min as compared to 5 â€‹h of nested PCR.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Giardia lamblia Limite: Child / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Giardia lamblia Limite: Child / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article