Your browser doesn't support javascript.
loading
Usefulness of new acoustic respiratory sound monitoring with artificial intelligence for upper airway assessment in obese patients during monitored anesthesia care.
Shimizu, Yoshitaka; Saeki, Noboru; Ohshimo, Shinichiro; Doi, Mitsuru; Oue, Kana; Yoshida, Mitsuhiro; Takahashi, Tamayo; Oda, Aya; Sadamori, Takuma; Tsutsumi, Yasuo M; Shime, Nobuaki.
Afiliação
  • Shimizu Y; Department of Dental Anesthesiology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
  • Saeki N; Department of Anesthesiology and Critical Care, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
  • Ohshimo S; Department of Emergency and Critical Care Medicine, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
  • Doi M; Department of Dental Anesthesiology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
  • Oue K; Department of Dental Anesthesiology, Division of Oral & Maxillofacial Surgery and Oral Medicine, Hiroshima University Hospital, Hiroshima, Japan.
  • Yoshida M; Department of Dental Anesthesiology, Division of Oral & Maxillofacial Surgery and Oral Medicine, Hiroshima University Hospital, Hiroshima, Japan.
  • Takahashi T; Department of Dental Anesthesiology, Division of Oral & Maxillofacial Surgery and Oral Medicine, Hiroshima University Hospital, Hiroshima, Japan.
  • Oda A; Department of Dental Anesthesiology, Division of Oral & Maxillofacial Surgery and Oral Medicine, Hiroshima University Hospital, Hiroshima, Japan.
  • Sadamori T; Department of Emergency and Critical Care Medicine, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
  • Tsutsumi YM; Department of Anesthesiology and Critical Care, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
  • Shime N; Department of Emergency and Critical Care Medicine, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
J Med Invest ; 70(3.4): 430-435, 2023.
Article em En | MEDLINE | ID: mdl-37940528
ABSTRACT
Monitored anesthesia care (MAC) often causes airway complications, particularly posing an elevated risk of aspiration and airway obstruction in obese patients. This study aimed to quantify the levels of aspiration and airway obstruction using an artificial intelligence (AI)-based acoustic analysis algorithm, assessing its utility in identifying airway complications in obese patients. To verify the correlation between the stridor quantitative value (STQV) calculated by acoustic analysis and body weight, and to further evaluate fluid retention and airway obstruction, STQV calculated exhaled breath sounds collected at the neck region, was compared before and after injection of 3 ml of water in the oral cavity and at the start and end of the MAC procedures. STQV measured immediately following the initiation of MAC exhibited a weak correlation with body mass index. Furhtermore, STQV values before and after water injection increased predominantly after injection, further increased at the end of MAC. AI-based analysis of cervical respiratory sounds can enhance the safety of airway management during MAC by quantifying airway obstruction and fluid retention in obese patients. J. Med. Invest. 70 430-435, August, 2023.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Obstrução das Vias Respiratórias / Anestesia Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Obstrução das Vias Respiratórias / Anestesia Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article