Photoelectrochemical Sensor with a Z-Scheme Fe2O3/CdS Heterostructure for Sensitive Detection of Mercury Ions.
Ren, Xiang; Chen, Jingui; Wang, Chao; Wu, Dan; Ma, Hongmin; Wei, Qin; Ju, Huangxian.
Afiliação
  • Ren X; State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, P. R. China.
  • Chen J; Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China.
  • Wang C; Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China.
  • Wu D; State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, P. R. China.
  • Ma H; Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China.
  • Wei Q; Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China.
  • Ju H; Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China.
Anal Chem ; 95(46): 16943-16949, 2023 11 21.
Article em En | MEDLINE | ID: mdl-37944013
ABSTRACT
Mercury (Hg2+) is a highly toxic element and can seriously affect human health. This work proposed a photoelectrochemical (PEC) sensor with a Z-scheme Fe2O3/CdS heterostructure and two thymine-rich DNA strands (DNA-1 and Au@DNA-2) for sensitive detection of Hg2+. The light excitation of the Fe2O3/CdS composite accelerated the electron transfer among Fe2O3, CdS, and the electrode to produce a stable photocurrent response. Upon the recognition of Hg2+ to thymine bases (T) in two DNA strands to form a stable T-Hg2+-T biomimetic structure, the photocurrent response increased with the increasing concentration of Hg2+ due to the opening of electronic transmission channels from Au nanoparticles to Fe2O3/CdS nanocomposite. Under the optimal conditions screened by the Box-Behnken experiments, the proposed PEC sensor showed excellent analytical performance for Hg2+ detection with high sensitivity, a detection limit of 0.20 pM at a signal-to-noise ratio of 3, high selectivity, a detectable concentration range of 1 pM-100 nM, and acceptable stability. The good recovery and low relative standard deviation for the analysis of Hg2+ in lake and tap water samples demonstrated the potential application of the designed Z-scheme Fe2O3/CdS heterostructure in the PEC detection of heavy metal ions.