Biomechanical investigation of a custom-made insole to decrease plantar pain of children with flatfoot: A technical note.
Guo, Junchao; Yang, Jiemeng; Pu, Jingyu; Ma, Fengling.
Afiliação
  • Guo J; Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, Key Laboratory of Human Motion Analysis and Rehabilitation Technology of the Ministry of Civil Affairs, National Research Center for Rehabilitation Technical Aids, 100176 Beijing, PR China. Electronic address: guojunchao
  • Yang J; Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, Key Laboratory of Human Motion Analysis and Rehabilitation Technology of the Ministry of Civil Affairs, National Research Center for Rehabilitation Technical Aids, 100176 Beijing, PR China.
  • Pu J; The Second Center Kindergarten of Yinghai Town, Daxing District, Beijing, PR China.
  • Ma F; Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, Key Laboratory of Human Motion Analysis and Rehabilitation Technology of the Ministry of Civil Affairs, National Research Center for Rehabilitation Technical Aids, 100176 Beijing, PR China.
Med Eng Phys ; 121: 104070, 2023 11.
Article em En | MEDLINE | ID: mdl-37985027
ABSTRACT

OBJECTIVE:

The abnormal plantar pressure of flatfoot patients is a common condition. The main objective of the present study was to investigate the effect of custom-molded insole on the plantar pain of flatfoot

METHODS:

105 patients (representing 174 feet) participated in evaluating a custom-made orthotic insole from June 2018 to March 2019. The height of the navicular tubercle (HNT) and the deflection angle of calcaneus (DAC) in flatfoot patients after using orthotic insoles for 6 months were recorded by X-ray imaging and scanning measurements. Plantar pressure on metatarsals 1-5 was measured by using an RSscan system

RESULTS:

Without the use of an orthotic insole, mean HNT was 0.99±0.34 cm and mean DAC was 20.0 ± 3.78 ° during the bearing weight. After using the insole, mean HNT and DAC values reduced to 0.87±0.30 cm and 14.3 ± 3.45 °, respectively (P < 0.05). Hindfoot plantar pressure did not change significantly (P > 0.05). Furthermore, pressure at metatarsals 1-3 decreased by 48.5 %, 45.6 %, and 14.3 %, respectively; that at metatarsals 4-5 increased by 33.3 % and 137.5 %, separately, when using the custom-made insole

CONCLUSIONS:

Visual analog scale score for plantar pain was significantly reduced. These findings indicate that metatarsal pain of flatfoot patients might be the cause of load imbalance in plantar foot.