Your browser doesn't support javascript.
loading
Magnetic Resonance Perfusion-Weighted Imaging in Predicting Hemorrhagic Transformation of Acute Ischemic Stroke: A Retrospective Study.
Li, Ming; Lv, Yifan; Wang, Mingming; Zhang, Yaying; Pan, Zilai; Luo, Yu; Zhang, Haili; Wang, Jing.
Afiliação
  • Li M; Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China.
  • Lv Y; Department of Radiology, Shanghai Fourth People's Hospital, School of Medicine, Tongji University, Shanghai 200434, China.
  • Wang M; Department of Radiology, Shanghai Fourth People's Hospital, School of Medicine, Tongji University, Shanghai 200434, China.
  • Zhang Y; Department of Radiology, Shanghai Fourth People's Hospital, School of Medicine, Tongji University, Shanghai 200434, China.
  • Pan Z; Department of Radiology, Shanghai Fourth People's Hospital, School of Medicine, Tongji University, Shanghai 200434, China.
  • Luo Y; Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200025, China.
  • Zhang H; Department of Radiology, Shanghai Fourth People's Hospital, School of Medicine, Tongji University, Shanghai 200434, China.
  • Wang J; Southeast University Hospital, Southeast University, Nanjing 210096, China.
Diagnostics (Basel) ; 13(22)2023 Nov 08.
Article em En | MEDLINE | ID: mdl-37998540
ABSTRACT
Hemorrhagic transformation (HT) is one of the common complications in patients with acute ischemic stroke (AIS). This study aims to investigate the value of different thresholds of Tmax generated from perfusion-weighted MR imaging (PWI) and the apparent diffusion coefficient (ADC) value in the prediction of HT in AIS. A total of 156 AIS patients were enrolled in this study, with 55 patients in the HT group and 101 patients in non-HT group. The clinical baseline data and multi-parametric MRI findings were compared between HT and non-HT groups to identify indicators related to HT. The optimal parameters for predicting HT and the corresponding cutoff values were obtained using the receiver operating characteristic curve analysis of the volumes of ADC < 620 × 10-6 mm2/s and Tmax > 6 s, 8 s, and 10 s. The results showed that the volumes of ADC < 620 × 10-6 mm2/s and Tmax > 6 s, 8 s, and 10 s in the HT group were all significantly larger than that in the non-HT group and were all independent risk factors for HT. Early measurement of the volume of Tmax > 10 s had the highest value, with a cutoff lesion volume of 10.5 mL.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article