Your browser doesn't support javascript.
loading
Magnetic Anomaly Detection Based on a Compound Tri-Stable Stochastic Resonance System.
Huang, Jinbo; Zheng, Zhen; Zhou, Yu; Tan, Yuran; Wang, Chengjun; Xu, Guangbo; Zha, Bingting.
Afiliação
  • Huang J; School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
  • Zheng Z; School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
  • Zhou Y; School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
  • Tan Y; School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
  • Wang C; School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
  • Xu G; School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
  • Zha B; School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
Sensors (Basel) ; 23(22)2023 Nov 20.
Article em En | MEDLINE | ID: mdl-38005680
ABSTRACT
In the case of strong background noise, a tri-stable stochastic resonance model has higher noise utilization than a bi-stable stochastic resonance (BSR) model for weak signal detection. However, the problem of severe system parameter coupling in a conventional tri-stable stochastic resonance model leads to difficulty in potential function regulation. In this paper, a new compound tri-stable stochastic resonance (CTSR) model is proposed to address this problem by combining a Gaussian Potential model and the mixed bi-stable model. The weak magnetic anomaly signal detection system consists of the CTSR system and judgment system based on statistical analysis. The system parameters are adjusted by using a quantum genetic algorithm (QGA) to optimize the output signal-to-noise ratio (SNR). The experimental results show that the CTSR system performs better than the traditional tri-stable stochastic resonance (TTSR) system and BSR system. When the input SNR is -8 dB, the detection probability of the CTSR system approaches 80%. Moreover, this detection system not only detects the magnetic anomaly signal but also retains information on the relative motion (heading) of the ferromagnetic target and the magnetic detection device.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article