Your browser doesn't support javascript.
loading
Virtual Injection Software Reduces Radiation Exposure and Procedural Time of Prostatic Artery Embolization Performed with Cone-Beam CT.
Barral, Matthias; Lassalle, Louis; Gardavaud, François; Lehrer, Raphael; Haffaf, Idriss; Agbonon, Rémi; Cussenot, Olivier; Cornelis, François H.
Afiliação
  • Barral M; Department of Radiology, Hôpital Tenon-Assistance Publique des Hôpitaux de Paris, Paris, France; Department of Interventional Radiology, Sorbonne Université, Paris, France; Sorbonne Université, Paris, France. Electronic address: matthiasbarral@gmail.com.
  • Lassalle L; Réseau d'imagerie Sud Francilien, Service de Radiologie, Évry, France; Ramsay Sante, Service de Radiologie, Clinique du Mousseau, Évry, France.
  • Gardavaud F; Department of Radiology, Hôpital Tenon-Assistance Publique des Hôpitaux de Paris, Paris, France.
  • Lehrer R; Department of Radiology, Hôpital Tenon-Assistance Publique des Hôpitaux de Paris, Paris, France; Department of Interventional Radiology, Sorbonne Université, Paris, France; Sorbonne Université, Paris, France.
  • Haffaf I; Department of Radiology, Hôpital Tenon-Assistance Publique des Hôpitaux de Paris, Paris, France.
  • Agbonon R; Department of Radiology, Hôpital Tenon-Assistance Publique des Hôpitaux de Paris, Paris, France; Department of Interventional Radiology, Sorbonne Université, Paris, France; Sorbonne Université, Paris, France.
  • Cussenot O; Sorbonne Université, Paris, France; Department of Urology, Hôpital Tenon-Assistance Publique des Hôpitaux de Paris, Paris, France.
  • Cornelis FH; Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York; Weill Cornell Medical College, New York, New York.
J Vasc Interv Radiol ; 35(3): 409-415, 2024 Mar.
Article em En | MEDLINE | ID: mdl-38008376
PURPOSE: To evaluate the impact of virtual injection software (VIS) use during cone-beam computed tomography (CT)-guided prostatic artery embolization (PAE) on both patient radiation exposure and procedural time. MATERIALS AND METHODS: This institutional review board (IRB)-approved comparative retrospective study analyzed the treatment at a single institution of 131 consecutive patients from January 2020 to May 2022. Cone-beam CT was used with (Group 1, 77/131; 58.8%) or without VIS (Group 2, 54/131, 41.2%). Radiation exposure (number of digital subtraction angiography [DSA] procedures), dose area product (DAP), total air kerma (AK), peak skin dose (PSD), fluoroscopy time (FT), and procedure time (PT) were recorded. The influences of age, body mass index, radial access, and use of VIS were assessed. RESULTS: In bivariate analysis, VIS use (Group 1) showed reduction in the number of DSA procedures (8.6 ± 3.7 vs 16.8 ± 4.3; P < .001), DAP (110.4 Gy·cm2 ± 46.8 vs 140.5 Gy·cm2 ± 61; P < .01), AK (642 mGy ± 451 vs 1,150 mGy ± 637; P = .01), PSD (358 mGy ± 251 vs 860 mGy ± 510; P = .001), FT (35.6 minutes ± 15.4 vs 46.6 minutes ± 20; P = .001), and PT (94.6 minutes ± 41.3 vs 115.2 minutes ± 39.6, P = .005) compared to those in Group 2. In multivariate analysis, AK, PSD, FT, and PT reductions were associated with VIS use (P < .001, P < .001, P = .001, and P = .006, respectively). CONCLUSIONS: The use of VIS during PAE performed under cone-beam CT guidance led to significant reduction in patient radiation exposure and procedural time.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hiperplasia Prostática / Exposição à Radiação / Embolização Terapêutica Limite: Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Hiperplasia Prostática / Exposição à Radiação / Embolização Terapêutica Limite: Humans / Male Idioma: En Ano de publicação: 2024 Tipo de documento: Article