Electrodeposition of paracetamol oxide for intelligent portable ratiometric detection of nicotine and ethyl vanillin ß-D-glucoside.
Analyst
; 149(1): 188-195, 2023 Dec 18.
Article
em En
| MEDLINE
| ID: mdl-38010128
Herein, the electrodeposition of paracetamol oxide (PA ox) for the intelligent portable ratiometric detection of nicotine (NIC) and ethyl vanillin ß-D-glucoside (EVG) is reported. PA ox electrodeposited on a screen-printed carbon electrode (SPCE) was used as a new fixed state ratiometric reference probe. A portable electrochemical workstation combined with a smart phone was applied as an intelligent portable electrochemical sensing platform. The sensor was studied by scanning electron microscopy (SEM), Fourier transform infrared spectrophotometry (FT-IR), ultraviolet-visible spectrophotometry (UV-vis), theoretical calculation, chronoamperometry, cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV). Under optimized conditions, the detection range of NIC is 10-200 µmol L-1, and the detection limit is 0.256 µmol L-1. The detection range of EVG was 10-180 µmol L-1, and the detection limit was 0.058 µmol L-1. The sensor can realize the real-time detection of NIC and EVG concentration in cigarette samples quickly and accurately, and has good anti-interference, repeatability and stability.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Acetaminofen
/
Nicotina
Idioma:
En
Ano de publicação:
2023
Tipo de documento:
Article