Unilateral intraindividual comparison and bilateral performance of a monofocal spherical and diffractive extended depth of field intraocular lens mix-and-match approach.
Wendelstein, Jascha A; Casazza, Marina; Reifeltshammer, Sophia; Riaz, Kamran; Pantanelli, Seth; Mariacher, Siegfried; Seiler, Theo G; Kohnen, Thomas; Bolz, Matthias.
Afiliação
  • Wendelstein JA; Medical Faculty, Johannes Kepler University Linz, Linz, Austria.
  • Casazza M; Department of Ophthalmology and Optometry, Kepler University Hospital GmbH, Johannes Kepler University Linz, Linz, Austria.
  • Reifeltshammer S; Institute of Experimental Ophthalmology, Saarland University, Homburg, Germany.
  • Riaz K; IROC-Institut für Refraktive und Ophthalmo-Chirurgie, Zürich, Switzerland.
  • Pantanelli S; Medical Faculty, Johannes Kepler University Linz, Linz, Austria.
  • Mariacher S; Department of Ophthalmology and Optometry, Kepler University Hospital GmbH, Johannes Kepler University Linz, Linz, Austria.
  • Seiler TG; Medical Faculty, Johannes Kepler University Linz, Linz, Austria.
  • Kohnen T; Department of Ophthalmology and Optometry, Kepler University Hospital GmbH, Johannes Kepler University Linz, Linz, Austria.
  • Bolz M; Dean A. McGee Eye Institute, University of Oklahoma, Oklahoma City, Oklahoma, USA.
Clin Exp Ophthalmol ; 52(1): 31-41, 2024.
Article em En | MEDLINE | ID: mdl-38050340
ABSTRACT

BACKGROUND:

To evaluate the intraindividual visual performance of a spherical and extended depth of field (EDOF) IOL used in a mix-and-match approach.

METHODS:

Single centre (tertiary care centre), retrospective consecutive case series. Included patients had uneventful cataract surgery with implantation of a spherical monofocal IOL (CT Spheris 204) in the dominant eye and a diffractive EDOF IOL (AT LARA 829) in the non-dominant eye. Monocular and binocular defocus curves and visual acuity at various distances were assessed. In addition, binocular reading speed, contrast sensitivity, and patient satisfaction using QOV, Catquest 9SF, and glare/halo questionnaires are reported.

RESULTS:

A total of 29 patients (58 eyes) were included. We observed significant intra-individual differences for monocular DCIVA, DCNVA, UIVA, and UNVA. There were no differences in monocular BCDVA or UDVA. The monocular defocus curves for the two IOLs significantly differed at defocus steps between -1.0 and -3.5 D. 93.10% of patients reported they would opt for the same combination of IOLs.

CONCLUSION:

Excellent uncorrected and corrected distance visual acuity was demonstrated in both groups. The mix-and-match approach described in this study yielded good intermediate vision and improved near vision with high-patient satisfaction.