Accuracy of digital implant impressions obtained using intraoral scanners: a systematic review and meta-analysis of in vivo studies.
Ma, Jie; Zhang, Binghua; Song, Hao; Wu, Dongle; Song, Tao.
Afiliação
  • Ma J; Department of Implant Dentistry, Shanghai Xuhui District Dental Center, No.500 Fenglin Road, Shanghai, 200032, China.
  • Zhang B; Department of Implant Dentistry, Shanghai Xuhui District Dental Center, No.500 Fenglin Road, Shanghai, 200032, China.
  • Song H; Department of Oral Maxillofacial-Head and Neck Oncology, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China.
  • Wu D; Department of Implant Dentistry, Shanghai Xuhui District Dental Center, No.500 Fenglin Road, Shanghai, 200032, China.
  • Song T; Department of Implant Dentistry, Shanghai Xuhui District Dental Center, No.500 Fenglin Road, Shanghai, 200032, China. 13701635237@139.com.
Int J Implant Dent ; 9(1): 48, 2023 Dec 06.
Article em En | MEDLINE | ID: mdl-38055096
PURPOSE: This systematic review aimed to investigate the accuracy of intraoral scan (IOS) impressions of implant-supported restorations in in vivo studies. METHODS: A systematic electronic search and review of studies on the accuracy of IOS implant impressions were conducted to analyze the peer-reviewed literature published between 1989 and August 2023. The bias analysis was performed by two reviewers. Data on the study characteristics, accuracy outcomes, and related variables were extracted. A meta-analysis of randomized control trials was performed to investigate the impact of IOS on peri-implant crestal bone loss and the time involved in the impression procedure. RESULTS: Ten in vivo studies were included in this systematic review for final analysis. Six studies investigated the trueness of IOS impressions, but did not reach the same conclusions. One study assessed the precision of IOS impressions for a single implant. Four clinical studies examined the accuracy of IOS implant impressions with a follow-up of 1-2 years. In full arches, IOS impression procedure needed significantly less time than conventional one (mean difference for procedure time was 8.59 min [6.78, 10.40 min], P < 0.001), prosthetic survival rate was 100%, and marginal bone levels of all participants could be stably maintained (mean difference in marginal bone loss at 12 months was 0.03 mm [-0.08, 0.14 mm], P = 0.55). CONCLUSIONS: The accuracy of IOS impressions of implant-supported restorations varied greatly depending on the scanning strategy. The trueness and precision of IOS in the partial and complete arches remain unclear and require further assessment. Based on follow-up clinical studies, IOS impressions were accurate in clinical practice. However, these results should be interpreted with caution, as some evidences are obtained from the same research group.