Your browser doesn't support javascript.
loading
Augmentative lag screws as a treatment for aseptic hypertrophic nonunion after internal fracture fixation.
Concha, Juan Manuel; Osma, Jose Luis; Fantín, Emilio; Concha, Carolina; Caicedo, Alvaro Jose.
Afiliação
  • Concha JM; Departamento de Ciencias Quirúrgicas, Universidad del Cauca, Popayán Colombia; Hospital Susana López de Valencia, Popayán, Colombia. Electronic address: juanconcha@unicauca.edu.co.
  • Osma JL; Universidad Industrial de Santander, Bucaramanga, Colombia. Electronic address: joseluis@uis.edu.co.
  • Fantín E; IUCBC Instituto Universitario de Ciencias Biomédicas, Cordoba, Argentina. Electronic address: emilio.fantin@IUCBC.edu.ar.
  • Concha C; Department Facultad de Medicina, Institution Pontificia, Universidad Javeriana, Bogotá, Colombia. Electronic address: conchac.a@javeriana.edu.co.
  • Caicedo AJ; Department Facultad de Medicina, Institution Pontificia, Universidad Javeriana, Cali, Colombia. Electronic address: alvaro65123@javerianacali.edu.co.
Injury ; 54 Suppl 6: 110805, 2023 Nov.
Article em En | MEDLINE | ID: mdl-38143134
ABSTRACT

BACKGROUND:

Hypertrophic nonunion after intramedullary (IM) nailing and plating is Uncommon and the treatment remained controversial. The aim of this study was to show the result of a simple augmentative lag screws technique for vital non-unions after internal fixation PATIENTS AND

METHODS:

We retrospectively reviewed the patients with nonunion after internal fixation between January 2016 to August 2022. Patients with unacceptable shortening or deformity were excluded as well as nonunion septic cases. All the patients were followed up for at least 6 months.

RESULTS:

Seven patients achieved bony union in a median time of 12 weeks (IRQ 12-16). There was a failure case with persistent non-union and brokerage of the screws.

DISCUSSION:

Various techniques have been described to treat non-union after intramedullary nailing or plating. The existing nail is frequently removed, and the non-union site is either re-reamed and re-nailed or fixed with a plate or external fixation devices or rechanged by a nail in the case of plates. In our study of non-union, augmentative lag screws were successfully applied to treat eight patients with aseptic nonunion, resulting in the healing of non-union in all cases except one.

CONCLUSION:

Augmentative lag screws represent a simple technique for the management of aseptic hypertrophic nonunion after internal fixation with a significantly shorter operating time.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas do Fêmur / Fixação Intramedular de Fraturas / Fraturas não Consolidadas Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fraturas do Fêmur / Fixação Intramedular de Fraturas / Fraturas não Consolidadas Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article