Your browser doesn't support javascript.
loading
Visualisation of microalgal lipid bodies through electron microscopy.
Verwee, Ellen; Van de Walle, Davy; De Bruyne, Michiel; Mienis, Esther; Sekulic, Mirna; Chaerle, Peter; Vyverman, Wim; Foubert, Imogen; Dewettinck, Koen.
Afiliação
  • Verwee E; Department of Food Technology, Food Structure & Function research group, Safety and Health, Ghent University, Ghent, Belgium.
  • Van de Walle D; Department of Biotechnology, Ghent University, Ghent, Belgium.
  • De Bruyne M; Department of Food Technology, Food Structure & Function research group, Safety and Health, Ghent University, Ghent, Belgium.
  • Mienis E; VIB BioImaging Core VIB, Ghent, Belgium.
  • Sekulic M; VIB Center for Inflammation Research VIB, Ghent, Belgium.
  • Chaerle P; Department of Biomedical Molecular Biology, Ghent University, Ghent, Belgium.
  • Vyverman W; Research Unit Food & Lipids, KU Leuven Kulak, Kortrijk, Belgium.
  • Foubert I; Leuven Food Science and Nutrition Research Centre (LFoRCe), KU Leuven, Leuven, Belgium.
  • Dewettinck K; Department of Biology, Laboratory of Protistology and Aquatic Ecology, Ghent University, Ghent, Belgium.
J Microsc ; 293(2): 118-131, 2024 Feb.
Article em En | MEDLINE | ID: mdl-38149687
ABSTRACT
In this study, transmission electron microscopy (TEM) and cryo-scanning electron microscopy (cryo-SEM) were evaluated for their ability to detect lipid bodies in microalgae. To do so, Phaeodactylum tricornutum and Nannochloropsis oculata cells were harvested in both the mid-exponential and early stationary growth phase. Two different cryo-SEM cutting methods were compared cryo-planing and freeze-fracturing. The results showed that, despite the longer preparation time, TEM visualisation preceded by cryo-immobilisation allows a clear detection of lipid bodies and is preferable to cryo-SEM. Using freeze-fracturing, lipid bodies were rarely detected. This was only feasible if crystalline layers in the internal structure, most likely related to sterol esters or di-saturated triacylglycerols, were revealed. Furthermore, lipid bodies could not be detected using cryo-planing. Cryo-SEM is also not the preferred technique to recognise other organelles besides lipid bodies, yet it did reveal chloroplasts in both species and filament-containing organelles in cryo-planed Nannochloropsis oculata samples.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microalgas Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Microalgas Idioma: En Ano de publicação: 2024 Tipo de documento: Article