Your browser doesn't support javascript.
loading
Upper Extremity Wounds Treated with Biodegradable Temporizing Matrix versus Collagen-Chondroitin Silicone Bilayer.
Wu, Shannon S; Wells, Michael; Ascha, Mona; Gatherwright, James; Chepla, Kyle J.
Afiliação
  • Wu SS; Department of Education, Cleveland Clinic Lerner College of Medicine, Cleveland, Ohio, United States.
  • Wells M; Department of Education, Case Western Reserve University School of Medicine, Cleveland, Ohio, United States.
  • Ascha M; Division of Plastic and Reconstructive Surgery, Department of Surgery, Northwestern University Feinberg School of Medicine, Chicago, Illinois, United States.
  • Gatherwright J; Division of Plastic Surgery, Department of Surgery, Cleveland Clinic Akron General, Akron, Ohio, United States.
  • Chepla KJ; Division of Plastic Surgery, Department of Surgery, MetroHealth Medical Center, Cleveland, Ohio, United States.
J Hand Microsurg ; 15(5): 340-350, 2023 Dec.
Article em En | MEDLINE | ID: mdl-38152680
ABSTRACT
Objective This study aims to compare outcomes between Novosorb Biodegradable Temporizing Matrix (BTM) and Integra collagen-chondroitin silicone for upper-extremity wound reconstruction. Methods This retrospective study analyzed adult patients who underwent wound reconstruction with either BTM or Integra at our institution between 2015 and 2020. Results Forty-eight patients were included 31 (64.6%) BTM and 17 (35.4%) Integra. Mean age was 44.0 (range 18-68) years. Age, race, sex, smoking, comorbidities, and defect size were similar between groups. Wound etiologies included 12 (25.0%) burn, 22 (45.8%) trauma, and others. Median template size was 133 cm 2 for BTM and 104 cm 2 for Integra ( p = 0.526). Skin grafting was performed after 14 (45.2%) and 14 (82.4%) wounds treated with BTM and Integra, respectively ( p = 0.028). Template complications of infection and dehiscence were comparable. Skin-graft complications occurred in five (35.7%) and three (21.4%) wounds in BTM and Integra, respectively ( p = 0.031). Skin-graft failure rates were comparable ( p = 0.121). Mean number of secondary procedures required after template placement was higher in the Integra group (BTM, 1.0; Integra, 1.9; p = 0.090). Final healing was achieved in 17 (54.8%) BTM and 11 (64.7%) Integra wounds ( p = 0.694). Median time to healing was 4.1 months after BTM and 2.6 months after Integra placement ( p = 0.014). Conclusion Compared with Integra, BTM achieved comparable wound healing and complication rates. Fewer secondary procedures and skin grafts were observed in BTM wounds, likely as a result of the coronavirus disease 2019 pandemic. At our institution, 100 cm 2 of product costs $850 for BTM and $3,150 for Integra, suggesting BTM as an economical alternative to fulfill the high functional and aesthetic requirements of upper-extremity wounds.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2023 Tipo de documento: Article