Your browser doesn't support javascript.
loading
Limited angular remodelling after in-situ fixation for slipped capital femoral epiphysis : A study on radiographs from the Swedish pediatric orthopaedic quality registry for SCFE.
Anderson, Mattias; Herngren, Bengt; Tropp, Hans; Risto, Olof.
Afiliação
  • Anderson M; Department of Orthopaedics, University Hospital, Linköping, 58185, Sweden. mattias.anderson@regionostergotland.se.
  • Herngren B; Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden. mattias.anderson@regionostergotland.se.
  • Tropp H; Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden.
  • Risto O; Futurum - Academy for Health and Care, Jönköping county council, Department of Orthopaedics, Ryhov county hospital, Jönköping, Sweden.
BMC Musculoskelet Disord ; 25(1): 11, 2024 Jan 02.
Article em En | MEDLINE | ID: mdl-38166971
ABSTRACT

BACKGROUND:

In Sweden, most children with slipped capital femoral epiphysis (SCFE) are operated on with a single smooth pin or a short-threaded screw, allowing further growth of the femoral neck. Using the Swedish Pediatric Orthopaedic Quality registry, SPOQ, we investigated whether angular remodelling occurs adjacent to the proximal femoral epiphysis after fixation of SCFE using implants, allowing continued growth of the femoral neck.

METHODS:

During 2008-2010 a total national population of 155 children were reported to the SPOQ registry. Following our strict inclusion criteria, radiographs of 51 hips were further assessed. The lateral Head Shaft Angle (HSA), the Nötzli 3-point α-angle, the anatomic α-angle, and the Anterior Offset Ratio (AOR) on the first postoperative radiographs and at follow-up were measured to describe the occurrence of remodelling. Slip severity was categorised as mild, moderate or severe according to postoperative HSA.

RESULTS:

Mean and SD values for the change in HSA were 3,7° (5,0°), for 3-point α-angle 6,8° (8,9°), and anatomic α-angle 13,0° (16,3°). The overall increase in AOR was 0,038 (0.069). There were no significant differences between the slip severity groups.

CONCLUSIONS:

We found limited angular remodelling after in situ fixation with smooth pins or short threaded screws for SCFE. The angular remodelling and the reduction of the CAM deformity was less than previously described after fixation of SCFE with similar implants. Results about the same magnitude with non-growth sparing techniques suggest that factors other than longitudinal growth of the femoral neck are important for angular remodelling.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ortopedia / Escorregamento das Epífises Proximais do Fêmur Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Child / Humans País/Região como assunto: Europa Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ortopedia / Escorregamento das Epífises Proximais do Fêmur Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Child / Humans País/Região como assunto: Europa Idioma: En Ano de publicação: 2024 Tipo de documento: Article