Your browser doesn't support javascript.
loading
Evaluation of the SsIR/NIE recombinant antigen ELISA for the follow up of patients infected by Strongyloides stercoralis: a diagnostic study.
Prato, Marco; Tamarozzi, Francesca; Tais, Stefano; Rizzi, Eleonora; Mazzi, Cristina; Buonfrate, Dora.
Afiliação
  • Prato M; Department of Infectious Tropical Diseases and Microbiology, IRCCS Sacro Cuore Don Calabria Hospital, Verona, Negrar di Valpolicella, Italy.
  • Tamarozzi F; Department of Infectious Tropical Diseases and Microbiology, IRCCS Sacro Cuore Don Calabria Hospital, Verona, Negrar di Valpolicella, Italy.
  • Tais S; Department of Infectious Tropical Diseases and Microbiology, IRCCS Sacro Cuore Don Calabria Hospital, Verona, Negrar di Valpolicella, Italy.
  • Rizzi E; Department of Infectious Tropical Diseases and Microbiology, IRCCS Sacro Cuore Don Calabria Hospital, Verona, Negrar di Valpolicella, Italy.
  • Mazzi C; Department of Infectious Tropical Diseases and Microbiology, IRCCS Sacro Cuore Don Calabria Hospital, Verona, Negrar di Valpolicella, Italy.
  • Buonfrate D; Department of Infectious Tropical Diseases and Microbiology, IRCCS Sacro Cuore Don Calabria Hospital, Verona, Negrar di Valpolicella, Italy.
Parasitology ; 151(3): 295-299, 2024 Mar.
Article em En | MEDLINE | ID: mdl-38185819
ABSTRACT
Some serology assays demonstrated useful for post-treatment monitoring of Strongyloides stercoralis infection. Serology frequently has low specificity, which might be improved by the use of recombinant antigens. The Strongy Detect ELISA is based on 2 recombinant antigens (SsIR and NIE) and proved good accuracy. Aim of this study was to evaluate the performance of this test for the post-treatment monitoring of strongyloidiasis. We tested 38 paired sera, with matched fecal tests results, stored in our biobank and originating from a randomized controlled trial. At baseline, all patients tested positive for at least 1 fecal assay among PCR, direct stool microscopy and agar plate culture. Patients were re-tested with both serology and fecal assays 12 months after treatment. Primary outcome was the relative reduction in optical density (OD) between baseline and follow up. We observed that about 95% samples showed a reduction between pre and post-treatment OD, with a median relative reduction of 93.9% (IQR 77.3%­98.1%). In conclusion, the test proved reliable for post-treatment monitoring. However, some technical issues, including that the threshold for positivity has not be predefined, and that a substantial number of samples showed overflow signals, need to be fixed to permit use in routine practice.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estrongiloidíase / Strongyloides stercoralis Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estrongiloidíase / Strongyloides stercoralis Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article