Your browser doesn't support javascript.
loading
Skeletal facial asymmetry: reliability of manual and artificial intelligence-driven analysis.
Kazimierczak, Natalia; Kazimierczak, Wojciech; Serafin, Zbigniew; Nowicki, Pawel; Jankowski, Tomasz; Jankowska, Agnieszka; Janiszewska-Olszowska, Joanna.
Afiliação
  • Kazimierczak N; Kazimierczak Private Dental Practice, 85-009 Bydgoszcz, Poland.
  • Kazimierczak W; Kazimierczak Private Dental Practice, 85-009 Bydgoszcz, Poland.
  • Serafin Z; Department of Radiology and Diagnostic Imaging, Collegium Medicum, Nicolaus Copernicus University in Torun, 85-067 Bydgoszcz, Poland.
  • Nowicki P; Department of Radiology and Diagnostic Imaging, Collegium Medicum, Nicolaus Copernicus University in Torun, 85-067 Bydgoszcz, Poland.
  • Jankowski T; Kazimierczak Private Dental Practice, 85-009 Bydgoszcz, Poland.
  • Jankowska A; Jankowscy Private Dental Practice, 68-200 Zary, Poland.
  • Janiszewska-Olszowska J; Jankowscy Private Dental Practice, 68-200 Zary, Poland.
Dentomaxillofac Radiol ; 53(1): 52-59, 2024 Jan 11.
Article em En | MEDLINE | ID: mdl-38214946
ABSTRACT

OBJECTIVES:

To compare artificial intelligence (AI)-driven web-based platform and manual measurements for analysing facial asymmetry in craniofacial CT examinations.

METHODS:

The study included 95 craniofacial CT scans from patients aged 18-30 years. The degree of asymmetry was measured based on AI platform-predefined anatomical landmarks sella (S), condylion (Co), anterior nasal spine (ANS), and menton (Me). The concordance between the results of automatic asymmetry reports and manual linear 3D measurements was calculated. The asymmetry rate (AR) indicator was determined for both automatic and manual measurements, and the concordance between them was calculated. The repeatability of manual measurements in 20 randomly selected subjects was assessed. The concordance of measurements of quantitative variables was assessed with interclass correlation coefficient (ICC) according to the Shrout and Fleiss classification.

RESULTS:

Erroneous AI tracings were found in 16.8% of cases, reducing the analysed cases to 79. The agreement between automatic and manual asymmetry measurements was very low (ICC < 0.3). A lack of agreement between AI and manual AR analysis (ICC type 3 = 0) was found. The repeatability of manual measurements and AR calculations showed excellent correlation (ICC type 2 > 0.947).

CONCLUSIONS:

The results indicate that the rate of tracing errors and lack of agreement with manual AR analysis make it impossible to use the tested AI platform to assess the degree of facial asymmetry.