Clinical effect of nice knot-assisted minimally invasive titanium elastic nail fixation to treat Robinson 2B midshaft clavicular fracture.
Kang, Yongqiang; Zhang, Qingqing; Ma, Yunhong; Zhou, Ming; Jia, Xueyuan; Lin, Fang; Wu, Yongwei; Rui, Yongjun.
Afiliação
  • Kang Y; Medical College, Soochow University, Suzhou, Jiangsu, China.
  • Zhang Q; Department of Traumatic Orthopedics, Wuxi Ninth People's Hospital, Soochow University, Liangxi Road, No.999, Binhu District, Wuxi, Jiangsu, China.
  • Ma Y; Department of Traumatic Orthopedics, Wuxi Ninth People's Hospital, Soochow University, Liangxi Road, No.999, Binhu District, Wuxi, Jiangsu, China.
  • Zhou M; Department of Traumatic Orthopedics, Wuxi Ninth People's Hospital, Soochow University, Liangxi Road, No.999, Binhu District, Wuxi, Jiangsu, China.
  • Jia X; Department of Traumatic Orthopedics, Wuxi Ninth People's Hospital, Soochow University, Liangxi Road, No.999, Binhu District, Wuxi, Jiangsu, China.
  • Lin F; Department of Traumatic Orthopedics, Wuxi Ninth People's Hospital, Soochow University, Liangxi Road, No.999, Binhu District, Wuxi, Jiangsu, China.
  • Wu Y; Department of Traumatic Orthopedics, Wuxi Ninth People's Hospital, Soochow University, Liangxi Road, No.999, Binhu District, Wuxi, Jiangsu, China. 13951515157@163.com.
  • Rui Y; Department of Traumatic Orthopedics, Wuxi Ninth People's Hospital, Soochow University, Liangxi Road, No.999, Binhu District, Wuxi, Jiangsu, China. wxswkryj123@126.com.
BMC Musculoskelet Disord ; 25(1): 59, 2024 Jan 13.
Article em En | MEDLINE | ID: mdl-38216916
ABSTRACT

BACKGROUND:

The treatment of completely displaced midshaft clavicle fractures is still controversial, especially Robinson 2B fractures. Titanium elastic nail (TEN) fixation is a good option for simple fractures, but no reports exist on its use in complex fractures. This study aimed to present a surgical method using the Nice knot-assisted TEN fixation to treat Robinson 2B midshaft clavicular fractures.

METHODS:

A retrospective analysis of 29 patients who underwent fixation with TEN and had a 1-year postoperative follow-up between 2016 and 2020 was performed. The fractures were classified as Robinson type 2B1 in 17 cases and type 2B2 in 12 cases. Length of the incision, postoperative shoulder function Disability of Arm Shoulder and Hand (DASH) score and Constant score, complications rate, and second surgical incision length were recorded.

RESULTS:

The length of the incision was 2-6 cm (average 3.7 cm). All incisions healed by first intention, and no infection or nerve injury occurred. The Constant score was 92-100 (average 96) and the DASH score was 0-6.2 (mean, 2.64). TEN bending and hypertrophic nonunion occurred in one case (3.4%) and implant irritation occurred in four cases (13.8%) Fixation implants were removed at 12-26 months (mean, 14.6 months) after surgery, and the length of the second incision was 1-2.5 cm (average 1.3 cm).

CONCLUSIONS:

Intramedullary fixation by TEN is approved as a suitable surgical technique in clavicular fracture treatment. Nice knot-assisted fixation provides multifragmentary fracture stabilization, contributing to good fracture healing. Surgeons should consider this technique in treating Robinson 2B midshaft clavicular fractures. TRIAL REGISTRATION Retrospectively registered. This study was approved by the Ethics Committee of Wuxi Ninth People's Hospital (LW20220021).