Evaluation of an adaptive, rule-based dosing algorithm to maintain therapeutic anticoagulation during atrial fibrillation ablation.
Kalscheur, Matthew M; Martini, Matthew R; Mahnke, Marcus; Osman, Fauzia; Modaff, Daniel S; Fleeman, Blake E; Kipp, Ryan T; Wright, Jennifer M; Medow, Joshua E.
Afiliação
  • Kalscheur MM; Division of Cardiovascular Medicine, Department of Medicine, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin.
  • Martini MR; Division of Cardiovascular Medicine, Department of Medicine, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin.
  • Mahnke M; Integrated Vital Medical Dynamics, LLC, Madison, Wisconsin.
  • Osman F; Department of Medicine, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin.
  • Modaff DS; Division of Cardiovascular Medicine, Department of Medicine, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin.
  • Fleeman BE; Division of Cardiovascular Medicine, Department of Medicine, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin.
  • Kipp RT; Division of Cardiovascular Medicine, Department of Medicine, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin.
  • Wright JM; Division of Cardiovascular Medicine, Department of Medicine, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin.
  • Medow JE; Integrated Vital Medical Dynamics, LLC, Madison, Wisconsin.
Cardiovasc Digit Health J ; 4(6): 173-182, 2023 Dec.
Article em En | MEDLINE | ID: mdl-38222102
ABSTRACT

Background:

Cerebral thromboembolism during atrial fibrillation (AF) ablation is an infrequent (0.17%) complication in part owing to strict adherence to intraprocedural anticoagulation. Failure to maintain therapeutic anticoagulation can lead to an increase in events, including silent cerebral ischemia.

Objective:

To evaluate a computerized, clinical decision support system (CDSS) to dose intraprocedural anticoagulation and determine if it leads to improved intraprocedural anticoagulation outcomes during AF ablation.

Methods:

The Digital Intern dosing algorithm is an adaptive, rule-based CDSS for heparin dosing. The initial dose is calculated from the patient's weight, baseline activated clotting time (ACT), and outpatient anticoagulant. Subsequent recommendations adapt based on individual patient ACT changes. Outcomes from 50 cases prior to algorithm introduction were compared to 139 cases using the algorithm.

Results:

Procedures using the dosing algorithm reached goal ACT (over 300 seconds) faster (17.6 ± 11.1 minutes vs 33.3 ± 23.6 minutes pre-algorithm, P < .001). ACTs fell below goal while in the LA (odds ratio 0.20 [0.10-0.39], P < .001) and rose above 400 seconds less frequently (odds ratio 0.21 [0.07-0.59], P = .003). System Usability Scale scores were excellent (96 ± 5, n = 7, score >80.3 excellent). Preprocedure anticoagulant, weight, baseline ACT, age, sex, and renal function were potential predictors of heparin dose to achieve ACT >300 seconds and final infusion rate.

Conclusion:

A heparin dosing CDSS based on rules and adaptation to individual patient response improved maintenance of therapeutic ACT during AF ablation and was rated highly by nurses for usability.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline / Prognostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Guideline / Prognostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article