Target volumes comparison between postoperative simulation magnetic resonance imaging and preoperative diagnostic magnetic resonance imaging for prone breast radiotherapy after breast-conserving surgery.
Jin, Ying; Zhao, Changhui; Wang, Lizhen; Su, Ya; Shang, Dongping; Li, Fengxiang; Wang, Jinzhi; Liu, Xijun; Li, Jianbin; Wang, Wei.
Afiliação
  • Jin Y; Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China.
  • Zhao C; Department of Oncology, Jinan Third People's Hospital, Jinan Cancer Hospital, Jinan, China.
  • Wang L; Department of Medical Physics, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China.
  • Su Y; Department of Medical Physics, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China.
  • Shang D; Department of Medical Physics, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China.
  • Li F; Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China.
  • Wang J; Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China.
  • Liu X; Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China.
  • Li J; Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China.
  • Wang W; Department of Radiation Oncology, Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China.
Cancer Med ; 13(3): e6956, 2024 Feb.
Article em En | MEDLINE | ID: mdl-38247382
ABSTRACT

BACKGROUND:

This study investigated the differences in target volumes between preoperative magnetic resonance imaging (MRIpre) and postoperative MRI (MRIpost) for breast radiotherapy after breast-conserving surgery (BCS) using deformable image registration (DIR). METHODS AND MATERIALS Seventeen eligible patients who underwent whole-breast irradiation in the prone position after BCS were enrolled. On MRIpre, the gross tumor volume (GTV) was delineated as GTVpre, which was then expanded by 10 mm to represent the preoperative lumpectomy cavity (LC), denoted as LCpre. The LC was expanded to the clinical target volume (CTV) and planning target volume (PTV) on the MRIpre and MRIpost, denoted as CTVpre, CTVpost, PTVpre, and PTVpost, respectively. The MIM software system was used to register the MRIpre and MRIpost using DIR. Differences were evaluated regarding target volume, distance between the centers of mass (dCOM), conformity index (CI), and degree of inclusion (DI). The relationship between CILC /CIPTV and the clinical factors was also assessed.

RESULTS:

Significant differences were observed in LC and PTV volumes between MRIpre and MRIpost (p < 0.0001). LCpre was 0.85 cm3 larger than LCpost, while PTVpre was 29.38 cm3 smaller than PTVpost. The dCOM between LCpre and LCpost was 1.371 cm, while that between PTVpre and PTVpost reduced to 1.348 cm. There were statistically significant increases in CI and DI for LCpost-LCpre and PTVpost-PTVpre (CI = 0.221, 0.470; DI = 0.472, 0.635). No obvious linear correlations (p > 0.05) were found between CI and GTV, primary tumor volume-to-breast volume ratio, distance from the primary tumor to the nipple and chest wall, and body mass index.

CONCLUSIONS:

Despite using DIR technology, the spatial correspondence of target volumes between MRIpre and MRIpost was suboptimal. Therefore, relying solely on preoperative diagnostic MRI with DIR for postoperative LC delineation is not recommended.