Your browser doesn't support javascript.
loading
A Portable and Disposable Electrochemical Sensor Utilizing Laser-Scribed Graphene for Rapid SARS-CoV-2 Detection.
Wang, Runzhong; Zhu, Bicheng; Young, Paul; Luo, Yu; Taylor, John; Cameron, Alan J; Squire, Christopher J; Travas-Sejdic, Jadranka.
Afiliação
  • Wang R; Centre for Innovative Materials and Health, School of Chemical Sciences, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand.
  • Zhu B; Centre for Innovative Materials and Health, School of Chemical Sciences, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand.
  • Young P; School of Chemical Sciences, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand.
  • Luo Y; MacDiarmid Institute for Advanced Materials and Nanotechnology, Victoria University of Wellington, Wellington 6012, New Zealand.
  • Taylor J; School of Biological Sciences, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand.
  • Cameron AJ; Maurice Wilkins Centre for Molecular Biodiscovery, The University of Auckland, Auckland 1142, New Zealand.
  • Squire CJ; Micro- and Nano-Technology Research Center, State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
  • Travas-Sejdic J; School of Biological Sciences, The University of Auckland, Private Bag 92019, Auckland 1142, New Zealand.
Biosensors (Basel) ; 14(1)2023 Dec 23.
Article em En | MEDLINE | ID: mdl-38248387
ABSTRACT
The COVID-19 pandemic caused by the virus SARS-CoV-2 was the greatest global threat to human health in the last three years. The most widely used methodologies for the diagnosis of COVID-19 are quantitative reverse transcription polymerase chain reaction (RT-qPCR) and rapid antigen tests (RATs). PCR is time-consuming and requires specialized instrumentation operated by skilled personnel. In contrast, RATs can be used in-home or at point-of-care but are less sensitive, leading to a higher rate of false negative results. In this work, we describe the development of a disposable, electrochemical, and laser-scribed graphene-based biosensor strips for COVID-19 detection that exploits a split-ester bond ligase system (termed 'EsterLigase') for immobilization of a virus-specific nanobody to maintain the out-of-plane orientation of the probe to ensure the efficacy of the probe-target recognition process. An anti-spike VHH E nanobody, genetically fused with the EsterLigase domain, was used as the specific probe for the spike receptor-binding domain (SP-RBD) protein as the target. The recognition between the two was measured by the change in the charge transfer resistance determined by fitting the electrochemical impedance spectroscopy (EIS) spectra. The developed LSG-based biosensor achieved a linear detection range for the SP-RBD from 150 pM to 15 nM with a sensitivity of 0.0866 [log(M)]-1 and a limit of detection (LOD) of 7.68 pM.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: COVID-19 / Grafite Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: COVID-19 / Grafite Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article