Towards Precision Medicine in Clinical Practice: Alinity C vs. UHPLC-MS/MS in Plasma Aripiprazole Determination.
Toja-Camba, Francisco José; Bandín-Vilar, Enrique; Hermelo-Vidal, Gonzalo; Feitosa-Medeiros, Carolina; Cañizo-Outeiriño, Antonio; Castro-Balado, Ana; Varela-Rey, Iria; Zarra-Ferro, Irene; Fernández-Ferreiro, Anxo; Mondelo-García, Cristina.
Afiliação
  • Toja-Camba FJ; Pharmacy Department, University Clinical Hospital of Santiago de Compostela (SERGAS), 15706 Santiago de Compostela, Spain.
  • Bandín-Vilar E; Clinical Pharmacology Group, Health Research Institute of Santiago de Compostela (IDIS), 15706 Santiago de Compostela, Spain.
  • Hermelo-Vidal G; Faculty of Pharmacy, University of Santiago de Compostela, 15782 Santiago de Compostela, Spain.
  • Feitosa-Medeiros C; Pharmacy Department, University Clinical Hospital of Santiago de Compostela (SERGAS), 15706 Santiago de Compostela, Spain.
  • Cañizo-Outeiriño A; Clinical Pharmacology Group, Health Research Institute of Santiago de Compostela (IDIS), 15706 Santiago de Compostela, Spain.
  • Castro-Balado A; Faculty of Pharmacy, University of Santiago de Compostela, 15782 Santiago de Compostela, Spain.
  • Varela-Rey I; Clinical Pharmacology Group, Health Research Institute of Santiago de Compostela (IDIS), 15706 Santiago de Compostela, Spain.
  • Zarra-Ferro I; Clinical Pharmacology Group, Health Research Institute of Santiago de Compostela (IDIS), 15706 Santiago de Compostela, Spain.
  • Fernández-Ferreiro A; Clinical Pharmacology Group, Health Research Institute of Santiago de Compostela (IDIS), 15706 Santiago de Compostela, Spain.
  • Mondelo-García C; Pharmacy Department, University Clinical Hospital of Santiago de Compostela (SERGAS), 15706 Santiago de Compostela, Spain.
Pharmaceutics ; 16(1)2024 Jan 12.
Article em En | MEDLINE | ID: mdl-38258114
ABSTRACT
Therapeutic drug monitoring improves the benefit-risk balance of antipsychotic therapy. Ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) is considered the gold-standard method for measuring plasma drug concentrations; however, the Alinity C system has emerged as a promising alternative. This is the first study aimed at comparing UHPLC-MS/MS versus Alinity C in measuring plasma concentrations of aripiprazole and dehydroaripiprazole. A total of 86 plasma samples were analyzed. The active moiety of aripiprazole was measured in 60 samples using both systems and 26 samples were analyzed twice using Alinity C with an intermediate period of 6 months to assess its reproducibility. Spearman's correlation revealed a good association between the two assays (rs = 0.96) and no significance differences were found by McNemar's test when classifying samples between infra-, supra- and therapeutic ranges. Passing-Bablock regression showed a good correlation among methods (rs = 0.93) and a slope of 1.12 indicating a slight tendency of Alinity C to measure higher values than UHPLC-MS/MS. In addition, a good intra-method correlation across the two sequential analyses with Alinity C was obtained (rs = 0.99). Nonetheless, clinical decisions could be different in 15% of the cases depending on the chosen method. No differences were found in active moiety determination by Alinity C depending on the concentration of aripiprazole and dehydroaripiprazole of the samples.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2024 Tipo de documento: Article