Your browser doesn't support javascript.
loading
Novel Artificial Intelligence-Based Assessment of Imaging Biomarkers in Full-Thickness Macular Holes: Preliminary Data from a Pivotal Trial.
Mariotti, Cesare; Mangoni, Lorenzo; Iorio, Silvia; Lombardo, Veronica; Fruttini, Daniela; Rizzo, Clara; Chhablani, Jay; Midena, Edoardo; Lupidi, Marco.
Afiliação
  • Mariotti C; Eye Clinic, Department of Experimental and Clinical Medicine, Polytechnic University of Marche, 60131 Ancona, Italy.
  • Mangoni L; Eye Clinic, Department of Experimental and Clinical Medicine, Polytechnic University of Marche, 60131 Ancona, Italy.
  • Iorio S; Eye Clinic, Department of Experimental and Clinical Medicine, Polytechnic University of Marche, 60131 Ancona, Italy.
  • Lombardo V; Eye Clinic, Department of Experimental and Clinical Medicine, Polytechnic University of Marche, 60131 Ancona, Italy.
  • Fruttini D; Department of Medicine and Surgery, University of Perugia, S. Maria della Misericordia Hospital, 06123 Perugia, Italy.
  • Rizzo C; Ophthalmic Unit, Department of Neurosciences, Biomedicine, and Movement Sciences, University of Verona, 37129 Verona, Italy.
  • Chhablani J; Department of Ophthalmology, UPMC Eye Center, University of Pittsburgh, Pittsburgh, PA 15213, USA.
  • Midena E; Department of Ophthalmology, University of Padova, 35128 Padova, Italy.
  • Lupidi M; IRCCS-Fondazione Bietti, 00198 Rome, Italy.
J Clin Med ; 13(2)2024 Jan 22.
Article em En | MEDLINE | ID: mdl-38276134
ABSTRACT
Artificial intelligence (AI)- and deep learning (DL)-based systems have shown significant progress in the field of macular disorders, demonstrating high performance in detecting retinal fluid and assessing anatomical changes during disease progression. This study aimed to validate an AI algorithm for identifying and quantifying prognostic factors in visual recovery after macular hole (MH) surgery by analyzing major optical coherence tomography (OCT) biomarkers. This study included 20 patients who underwent vitrectomy for a full-thickness macular hole (FTMH). The mean diameter of the FTMH was measured at 285.36 ± 97.4 µm. The preoperative best-corrected visual acuity (BCVA) was 0.76 ± 0.06 logMAR, improving to 0.38 ± 0.16 postoperatively, with a statistically significant difference (p = 0.001). AI software was utilized to assess biomarkers, such as intraretinal fluid (IRF) and subretinal fluid (SRF) volume, external limiting membrane (ELM) and ellipsoid zone (EZ) integrity, and retinal hyperreflective foci (HRF). The AI analysis showed a significant decrease in IRF volume, from 0.08 ± 0.12 mm3 preoperatively to 0.01 ± 0.01 mm3 postoperatively. ELM interruption improved from 79% ± 18% to 34% ± 37% after surgery (p = 0.006), whereas EZ interruption improved from 80% ± 22% to 40% ± 36% (p = 0.007) postoperatively. Additionally, the study revealed a negative correlation between preoperative IRF volume and postoperative BCVA recovery, suggesting that greater preoperative fluid volumes may hinder visual improvement. The integrity of the ELM and EZ was found to be essential for postoperative visual acuity improvement, with their disruption negatively impacting visual recovery. The study highlights the potential of AI in quantifying OCT biomarkers for managing MHs and improving patient care.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2024 Tipo de documento: Article