Your browser doesn't support javascript.
loading
Development of Neutron Interferometer Using Multilayer Mirrors and Measurements of Neutron-Nuclear Scattering Length with Pulsed Neutron Source.
Fujiie, Takuhiro; Hino, Masahiro; Hosobata, Takuya; Ichikawa, Go; Kitaguchi, Masaaki; Mishima, Kenji; Seki, Yoshichika; Shimizu, Hirohiko M; Yamagata, Yutaka.
Afiliação
  • Fujiie T; Department of Physics, Nagoya University, Furocho Chikusa, Nagoya 464-8602, Aichi, Japan.
  • Hino M; RIKEN Center for Advanced Photonics, Hirosawa 2-1, Wako 351-0198, Saitama, Japan.
  • Hosobata T; Institute for Integrated Radiation and Nuclear Science, Kyoto University, 2, Asashiro-Nishi, Kumatori, Sennan-gun 590-0494, Osaka, Japan.
  • Ichikawa G; RIKEN Center for Advanced Photonics, Hirosawa 2-1, Wako 351-0198, Saitama, Japan.
  • Kitaguchi M; High Energy Accelerator Research Organization, Tokai, Ibaraki 319-1106, Japan.
  • Mishima K; J-PARC Center, 2-4 Tokai, Ibaraki 319-1195, Japan.
  • Seki Y; Department of Physics, Nagoya University, Furocho Chikusa, Nagoya 464-8602, Aichi, Japan.
  • Shimizu HM; High Energy Accelerator Research Organization, Tokai, Ibaraki 319-1106, Japan.
  • Yamagata Y; Kobayashi-Maskawa Institute, Nagoya University, Furocho Chikusa, Nagoya 464-8602, Aichi, Japan.
Phys Rev Lett ; 132(2): 023402, 2024 Jan 12.
Article em En | MEDLINE | ID: mdl-38277600
ABSTRACT
This study entailed the successful deployment of a novel neutron interferometer that utilizes multilayer mirrors. The apparatus facilitates a precise evaluation of the wavelength dependence of interference fringes utilizing a pulsed neutron source. Our interferometer achieved an impressive precision of 0.02 rad within a 20-min recording time. Compared to systems using silicon crystals, the measurement sensitivity was maintained even when using a simplified disturbance suppressor. By segregating beam paths entirely, we achieved successful measurements of neutron-nuclear scattering lengths across various samples. The values measured for Si, Al, and Ti were in agreement with those found in the literature, while V showed a disparity of 45%. This discrepancy may be attributable to impurities encountered in previous investigations. The accuracy of measurements can be enhanced further by mitigating systematic uncertainties that are associated with neutron wavelength, sample impurity, and thickness. This novel neutron interferometer enables us to measure fundamental parameters, such as the neutron-nuclear scattering length of materials, with a precision that surpasses that of conventional interferometers.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article