Your browser doesn't support javascript.
loading
[Feasibility of a novel type of complex anterior cervical fixation by using Mimics software].
Hou, Zhi-Peng; Ye, Sen-Qi; Zhang, Ji-Hui; Zhao, Liu-Jun; Gu, Yong-Jie; Yu, Liang.
Afiliação
  • Hou ZP; Health Science Center, Ningbo University, Ningbo 315211, Zhejiang, China.
  • Ye SQ; Health Science Center, Ningbo University, Ningbo 315211, Zhejiang, China.
  • Zhang JH; Department of Spinal Surgery, Ningbo No.6 Hospital, Ningbo 315040, Zhejiang, China.
  • Zhao LJ; Department of Spinal Surgery, Ningbo No.6 Hospital, Ningbo 315040, Zhejiang, China.
  • Gu YJ; Department of Spinal Surgery, Ningbo No.6 Hospital, Ningbo 315040, Zhejiang, China.
  • Yu L; Department of Spinal Surgery, Ningbo No.6 Hospital, Ningbo 315040, Zhejiang, China.
Zhongguo Gu Shang ; 37(1): 81-5, 2024 Jan 25.
Article em Zh | MEDLINE | ID: mdl-38286456
ABSTRACT

OBJECTIVE:

To investigate the feasibility of mimics software in analyzing a new type of complex anterior cervical fixation -- anterior transpedicular screw fixation+zero notch internal fixation.

METHODS:

From January 2021 to September 2022, 50 normal pedestrians who underwent cervical spine CT scanning were selected for C1-C7 segment scanning, including 27 males and 23 females, aged from 25 to 65 years old with an average of (46.0 ± 9.0) years old. The dicom format is exported and engraved into the CD, and use the mimics software to perform 3D reconstruction of each segment. A simulated screw is placed on the image according to the critical value of zero notch screw (head and tail angle 44°, internal angle 29°). The position of zero notch screw in each segment is observed to determine the feasibility of anterior transpedicular screw fixation plus zero notch internal fixation.

RESULTS:

For the upper zero notch screws the three-dimensional images of the cervical spine across all 50 subjects within the C3-C7 segments demonstrated safe position, with no instances of intersection with ATPS. For the lower zero notch screw, in C3-C4 and C4-C5, 4 out of 50 subjects are in the safe position in the three-dimensional images of cervical vertebrae, and 46 cases could achieve secure screw placement when the maximum caudal angle is(32.3±1.9) ° and (36.1±2.2) °, respectively. In C5-C6 and C6-C7 segments, no lower zero notch screws intersected with ATPS, and all screws are in safe positions.

CONCLUSION:

Lower cervical anterior pedicle screw fixation plus zero notch internal fixation can achieve successful nail placement through the selected entry point and position.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Parafusos Pediculares Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: Zh Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Parafusos Pediculares Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: Zh Ano de publicação: 2024 Tipo de documento: Article