Clinical application of instant 3D printed cast versus polymer orthosis in the treatment of colles fracture: a randomized controlled trial.
Xiao, Ya-Ping; Xu, Hai-Jia; Liao, Wen; Li, Zhang-Hua.
Afiliação
  • Xiao YP; The Department of Orthopedic Surgery, Wuhan Third Hospital, Tongren Hospital of Wuhan University, No. 241, Pengliuyang Road, Wuhan, 430000, Hubei Province, P.R. China.
  • Xu HJ; The Department of Orthopedic Surgery, Wuhan Third Hospital, Tongren Hospital of Wuhan University, No. 241, Pengliuyang Road, Wuhan, 430000, Hubei Province, P.R. China.
  • Liao W; The Department of Orthopedic Surgery, Wuhan Third Hospital, Tongren Hospital of Wuhan University, No. 241, Pengliuyang Road, Wuhan, 430000, Hubei Province, P.R. China.
  • Li ZH; The Department of Orthopedic Surgery, Wuhan Third Hospital, Tongren Hospital of Wuhan University, No. 241, Pengliuyang Road, Wuhan, 430000, Hubei Province, P.R. China. 18971610121@qq.com.
BMC Musculoskelet Disord ; 25(1): 104, 2024 Jan 31.
Article em En | MEDLINE | ID: mdl-38297262
ABSTRACT

BACKGROUND:

The shortcomings of plaster in water resistance, air permeability, skin comfort, fixed stability and weight of wearing are still to be solved. 3D printed cast can overcome the above shortcomings. At present, there is a relative lack of data on the clinical application of 3D printed cast, probably due to its complexity, relatively long operating time, and high price. We aimed to compare and evaluate the short-term effectiveness, safety and advantages of 3D printed wrist cast versus polymer orthosis in the treatment of Colles fracture.

METHODS:

Forty patients with Colles fracture in our hospital from June to December 2022 were selected and divided into an observation group (20 patients, treated with instant 3D printed cast) and a control group (20 cases, treated with polymer orthosis). Both groups treated with manual reduction and external fixation. The visual analogue scale (VAS), immobilization effectiveness and satisfaction scores, Disability of the Arm, Shoulder and Hand (DASH) score, complications and imaging data were collected and compared before immobilization and at 2, 6 and 12 weeks after the fracture.

RESULTS:

VAS at 2 weeks after the fracture was significantly lower in the observation group than in the control group ( P < 0.05). The immobilization effectiveness and satisfaction scores at 6 weeks after the fracture were significantly higher in the observation group than in the control group (all P < 0.05). The DASH scores at 2 and 6 weeks after the fracture were significantly lower in the observation group than in the control group (all P < 0.05). There wasn't rupture of the printed cast or orthosis in both groups. There were 2 cases of skin irritation in the control group, and no skin irritation occurred in the observation group. The palmar tilt angle and ulnar inclination angle at 2 weeks and 12 weeks after the fracture were significantly higher in the observation group than in the control group (all P < 0.05).

CONCLUSIONS:

Both instant 3D printed cast and polymer orthosis are effective in the treatment of Colles fracture. But instant 3D printed cast is better than polymer orthosis in areas of good clinical and imaging performance, and high patient satisfaction and comfort.