[68Ga]Ga-FAPI-46 synthesis on a GAIA® module system: Thorough study of the automated radiolabeling reaction conditions.
Rubira, Léa; Donzé, Charlotte; Fouillet, Juliette; Algudo, Benjamin; Kotzki, Pierre Olivier; Deshayes, Emmanuel; Fersing, Cyril.
Afiliação
  • Rubira L; Nuclear medicine department, Institut régional du Cancer de Montpellier (ICM), Univ. Montpellier, Montpellier, France.
  • Donzé C; Nuclear medicine department, Institut régional du Cancer de Montpellier (ICM), Univ. Montpellier, Montpellier, France.
  • Fouillet J; Nuclear medicine department, Institut régional du Cancer de Montpellier (ICM), Univ. Montpellier, Montpellier, France.
  • Algudo B; Nuclear medicine department, Institut régional du Cancer de Montpellier (ICM), Univ. Montpellier, Montpellier, France.
  • Kotzki PO; Nuclear medicine department, Institut régional du Cancer de Montpellier (ICM), Univ. Montpellier, Montpellier, France; Institut de Recherche en Cancérologie de Montpellier (IRCM), INSERM U1194, Univ. Montpellier, Institut régional du Cancer de Montpellier (ICM), Montpellier, France.
  • Deshayes E; Nuclear medicine department, Institut régional du Cancer de Montpellier (ICM), Univ. Montpellier, Montpellier, France; Institut de Recherche en Cancérologie de Montpellier (IRCM), INSERM U1194, Univ. Montpellier, Institut régional du Cancer de Montpellier (ICM), Montpellier, France.
  • Fersing C; Nuclear medicine department, Institut régional du Cancer de Montpellier (ICM), Univ. Montpellier, Montpellier, France; IBMM, Univ Montpellier, CNRS, ENSCM, Montpellier, France. Electronic address: cyril.fersing@icm.unicancer.fr.
Appl Radiat Isot ; 206: 111211, 2024 Apr.
Article em En | MEDLINE | ID: mdl-38309117
ABSTRACT
The influence of several parameters involved in the 68Ga radiolabeling of FAPI-46 was studied at the scale of the automated reaction. Among the buffers tested, HEPES 0.3 M pH 4 allowed both high radiochemical purity (RCP) and radiochemical yield (RCY), without prepurification of 68Ga but after final purification of [68Ga]Ga-FAPI-46 on a C18 cartridge. A longer reaction time did not show significant benefit on the RCP, while higher loads of FAPI-46 and gentisic acid as anti-radiolysis compound allowed better RCY.