A Phase 2 Trial to Test Safety and Efficacy of ST-100, a Unique Collagen Mimetic Peptide Ophthalmic Solution for Dry Eye Disease.
Baratta, Robert O; Schlumpf, Eric; Del Buono, Brian J; DeLorey, Shawn; Ousler, George; Calkins, David J.
Afiliação
  • Baratta RO; Stuart Therapeutics, Inc., Stuart, Florida.
  • Schlumpf E; Stuart Therapeutics, Inc., Stuart, Florida.
  • Del Buono BJ; Stuart Therapeutics, Inc., Stuart, Florida.
  • DeLorey S; Stuart Therapeutics, Inc., Stuart, Florida.
  • Ousler G; Ora Clinical, Inc., North Andover, Massachusetts.
  • Calkins DJ; Vanderbilt Eye Institute, Vanderbilt University Medical Center, Nashville, Tennessee.
Ophthalmol Sci ; 4(3): 100451, 2024.
Article em En | MEDLINE | ID: mdl-38317866
ABSTRACT

Objective:

Dry eye disease (DED) is a worldwide source of ocular discomfort. This first-in-human phase 2 clinical study determined the efficacy of treating signs and symptoms of DED using an ophthalmic solution of synthesized mimetic of human collagen (ST-100).

Design:

This double-masked, randomized, study compared high (60 µg/mL) and low (22 µg/mL) dose ST-100 to vehicle utilizing the Ora, Inc. Controlled Adverse Environment (CAE) during a 28-day period.

Participants:

Participants included males and females ≥ 18 years of age with signs and symptoms of DED for ≥ 6 months that worsened during CAE exposure who were not taking any topical prescription therapeutic. Intervention Participants applied ST-100 or vehicle placebo topically to both corneas (1 drop) twice daily via a blow-fill-sealed preservative-free container. Main Outcome

Measures:

The prespecified primary efficacy sign end point was mean change from baseline (CFB) in total corneal fluorescein staining, and the primary symptom end point was mean CFB in ocular discomfort. A secondary prespecified efficacy end point was CFB in unanesthetized Schirmer's test for tear film production.

Results:

Of 160 subjects in the intent-to-treat population (112 female, 48 male, median age 64), 146 completed the study. Total corneal fluorescein staining CFB improved for high-dose ST-100, with superiority over vehicle when both eyes were considered together (2-sample t test P = 0.0394). High-dose ST-100 was superior to vehicle in Schirmer's CFB for the study eye (least squares mean difference [confidence interval] = 2.3 [0.6, 4.0], P = 0.0094). For study eyes, the proportion of Schirmer's test responders (CFB ≥ 10 mm, Schirmer's responder rate) was 12.2% for high-dose ST-100 versus 0.0% for vehicle (P = 0.0266). The CFB for ocular discomfort score improved in study eyes for high- and low-dose ST-100 (paired t test, P = 0.0133, P = 0.0151, respectively) but without superiority over vehicle (ANCOVA P = 0.5696, P = 0.8968, respectively). ST-100 Schirmer's responders also demonstrated total elimination of worsening of corneal fluorescein stain during the stress of CAE sessions.

Conclusions:

ST-100 significantly improved tear production and related outcomes in DED and was well-tolerated in reducing symptoms. Financial Disclosures Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.