Your browser doesn't support javascript.
loading
Assessing intraoperative pedicle screw placement accuracy using biplanar radiographs compared to three-dimensional imaging.
Gorgy, George; Avrumova, Fedan; Paschal, Philip K; Paschal, Gregory K; Carrino, John A; Lebl, Darren R.
Afiliação
  • Gorgy G; Department of Spine Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
  • Avrumova F; Department of Spine Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
  • Paschal PK; Department of Spine Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
  • Paschal GK; Department of Spine Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
  • Carrino JA; Department of Radiology, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
  • Lebl DR; Department of Spine Surgery, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA. research@leblspinemd.com.
J Robot Surg ; 18(1): 68, 2024 Feb 08.
Article em En | MEDLINE | ID: mdl-38329623
ABSTRACT
To date, biplanar imaging (2D) has been the method of choice for pedicle screw (PS) positioning and verified for the anteroposterior view and (spinal midline) M-line method. In recent years, the use of intraoperative three-dimensional (3D) imaging has become available with the Gertzbein-Robbins system (GRS) to assess PS breach and positioning confirmation. The aim is to determine if 2D imaging is sufficient to assess PS position in comparison to advanced 3D imaging.Retrospective review of prospectively collected data from 204 consecutive adult patients who underwent posterior thoracic and lumbar instrumented fusion for degenerative spinal surgery by a single surgeon (2019-2022).Of the 204 patients, 187 (91.6%) had intraoperative images available for analysis. A total of 1044 PS implants were used; 922 (88.3%) were robotically placed. Postoperative CT scans were verified with M-line/GRS findings. Among 103 patients (50.5%) with a total of 362 screws, (34.7%) had postoperative CT, intraoperative 3D scan, and intraoperative 2D scan for analysis. Postoperative CT findings were consistent with all GRS findings, validating that 3D imaging was accurate. Screws (1%) were falsely verified by the M-line as 3D imaging confirmed false negative or positive findings.In our series, intraoperative 3D scan was as accurate as postoperative CT scan in assessing PS breach. A significant number of PS may be falsely read as accurate on 2D imaging, that is in fact inaccurate when assessed on 3D imaging. An intraoperative post-instrumentation 3D scan may be preferable to prevent postoperative recognition of a falsely verified screw on biplanar imaging.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos Cirúrgicos Robóticos / Parafusos Pediculares Tipo de estudo: Diagnostic_studies Limite: Adult / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos Cirúrgicos Robóticos / Parafusos Pediculares Tipo de estudo: Diagnostic_studies Limite: Adult / Humans Idioma: En Ano de publicação: 2024 Tipo de documento: Article