Your browser doesn't support javascript.
loading
Assessing Matrix Solid-Phase Dispersion Extraction Strategies for Determining Bisphenols and Phthalates in Gilthead Sea Bream Samples.
Soliz, Dulce L; Garcinuño, Rosa Ma; Paniagua González, Gema; Bravo, Juan Carlos; Fernández Hernando, Pilar.
Afiliação
  • Soliz DL; Department of Analytical Science, Faculty of Science, National University of Distance Education, UNED, Las Rozas, 28232 Madrid, Spain.
  • Garcinuño RM; Department of Analytical Science, Faculty of Science, National University of Distance Education, UNED, Las Rozas, 28232 Madrid, Spain.
  • Paniagua González G; Department of Analytical Science, Faculty of Science, National University of Distance Education, UNED, Las Rozas, 28232 Madrid, Spain.
  • Bravo JC; Department of Analytical Science, Faculty of Science, National University of Distance Education, UNED, Las Rozas, 28232 Madrid, Spain.
  • Fernández Hernando P; Department of Analytical Science, Faculty of Science, National University of Distance Education, UNED, Las Rozas, 28232 Madrid, Spain.
Foods ; 13(3)2024 Jan 27.
Article em En | MEDLINE | ID: mdl-38338548
ABSTRACT
Microplastics (MPs) and nanoplastics (NPs) are widely spread in the environment, generating significant concern due to their potential impact on environmental health. Marine species usually ingest plastic fragments, mistaking them for food. Many toxic compounds, such as plastic additives that are not chemically bound to the plastic matrix, can be released from MPs and NPs and reach humans via the food chain. This paper highlights the development and validation of a straightforward solid-liquid extraction clean-up procedure in combination with a matrix solid-phase dispersion method using high-performance liquid chromatography coupled with mass spectrometry (HPLC-MS) detection, enabling facile, precise, and reliable identification and quantitation of a total of six bisphenols and phthalates in gilthead sea breams. Under the optimized conditions, the developed method showed good linearity (R2 > 0.993) for all target compounds. The recoveries obtained were between 70 and 92%. The relative standard deviations (RSDs) for reproducibility (inter-day) and repeatability (intra-day) were less than 9% and 10%, respectively. The limit of detection (LOD) and limit of quantification (LOQ) for the target compounds ranged from 0.11 to 0.68 µg/kg and from 0.37 to 2.28 µg/kg, respectively. A new, efficient extraction methodology for the determination of BPA, BPS, BPF, DBP, DEP, and DHEP in gilthead seabream has been optimized and validated.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article