Simultaneous Detection of Prolactin and Growth Hormone Using a Dual-label Time-resolved Fluorescence Immunoassay.
Zhong, Shuhai; Liang, Huankun; Peng, Fenglan; Lu, Yanhong; Liu, Tiancai; Kulchytski, Uladzimir; Dong, Wenqi.
Afiliação
  • Zhong S; Guangzhou Yidenuo Biotechnology Co., Ltd., Guangzhou, 510663, China.
  • Liang H; Jinan Laide Biotechnology Co., Ltd., Jinan, 271100, China.
  • Peng F; Taian Disabled Soldiers' Hospital of Shandong Province, Taian, 271099, China.
  • Lu Y; Jinan Laide Biotechnology Co., Ltd., Jinan, 271100, China.
  • Liu T; School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, 510515, China.
  • Kulchytski U; Institute of Physiology, National Academy of Sciences of Belarus, Minsk, 220072, Republic of Belarus.
  • Dong W; Guangzhou Zhenda Biopharmaceutical Technology Co., Ltd., No. 3 Juquan Road, Huangpu District, Guangzhou, 510663, China. dongwenqi63@163.com.
J Fluoresc ; 2024 Feb 13.
Article em En | MEDLINE | ID: mdl-38349483
ABSTRACT
Prolactin (PRL) and growth hormone (GH) are two important hormones secreted by the pituitary gland, and their abnormal levels are often related to disease status. This study aimed to establish a new dual-label time-resolved fluorescence immunoassay (TRFIA) to quantitatively measure PRL and GH levels in serum. A sandwich TRFIA was optimized and established anti-PRL/GH antibodies immobilized on 96-well plates captured PRL/GH and then banded together with anti-PRL/GH paired antibodies labeled with europium(III) (Eu3+)/samarium(III) (Sm3+) chelates. Finally, a time-resolved analyzer measured the Eu3+/Sm3+ fluorescence values. Clinical serum samples were used to evaluate the detection performance of this method. The sensitivities of this dual-label TRFIA were 0.35 ng/mL and 0.45 ng/mL, respectively, and the detection range was between 0.1 and 1000 ng/mL. All the cross-reactivities were lower than 1.07%. The intra-assay and interassay coefficients of variation were 2.18-7.85% and 2.25-7.30%, respectively. Compared with the registered TRFIA kits, a high Pearson coefficient (r = 0.9626 and 0.9675) was observed. This dual-label TRFIA has high sensitivity, accuracy and specificity with good clinical detection performance, representing a suitable alternative to existing methods for determining PRL and GH levels, and is expected to be used in the clinic in the future.