Your browser doesn't support javascript.
loading
Gas chromatography-mass spectrometry selected ion monitoring and gas chromatography-tandem mass spectrometry selected reaction monitoring analyses of mono-, di- and tri-unsaturated C25 highly branched isoprenoid alkene biomarkers in sea ice and sediment samples: A comparative study.
Rontani, Jean-François; Smik, Lukas; Divine, Dmitry; Husum, Katrine; Belt, Simon T.
Afiliação
  • Rontani JF; Aix-Marseille University, Université de Toulon, CNRS/INSU/IRD, Mediterranean Institute of Oceanography (MIO), UM 110, Marseille, France.
  • Smik L; Biogeochemistry Research Centre, School of Geography, Earth and Environmental Sciences, University of Plymouth, Plymouth, UK.
  • Divine D; Centre for Resilience in Environment, Water and Waste, College of Life and Environmental Sciences, University of Exeter, Exeter, UK.
  • Husum K; Norwegian Polar Institute, Fram Centre, Tromsø, Norway.
  • Belt ST; Norwegian Polar Institute, Fram Centre, Tromsø, Norway.
Rapid Commun Mass Spectrom ; 38(6): e9704, 2024 Mar 30.
Article em En | MEDLINE | ID: mdl-38356092
ABSTRACT
RATIONALE The efficiency of selected ion monitoring (SIM) and selected reaction monitoring (SRM) analyses for the quantification of three mono-, di- and tri-unsaturated highly branched isoprenoid (HBI) alkenes (IP25 , IPSO25 and HBI III, respectively), often used as proxies for the occurrence of Arctic and Antarctic sea ice or the adjacent open waters, was compared.

METHODS:

Gas chromatography (GC)-mass spectrometry (MS)/SIM and GC/MS/MS/SRM analyses were carried out on dilute solutions made from purified standards of these three HBIs, and then on hydrocarbon fractions of several sediment and sea ice sample extracts. More efficient and specific SRM transitions were selected after collision-induced dissociation of each precursor ion at different collision energies.

RESULTS:

SRM analysis avoided any overestimation of IP25 resulting from the contribution of the coeluting 13 C mass isotopomer of IPSO25 (M+ ˙ + 2) to the SIM target ion. In contrast, SRM analysis is less reliable for IPSO25 quantification in cases where several regio-isomers are present, likely due to intense double bond migrations following electron impact. In the case of HBI III, SRM analysis constitutes a potentially suitable alternative to SIM analysis, especially in terms of improving limit of detection.

CONCLUSIONS:

Despite the intense migrations of HBI double bonds under electron ionization, the selected SRM transitions should be more suitable than SIM target ions for IP25 and HBI III quantification in complex hydrocarbon fractions of natural samples. However, the advantage is less evident for IPSO25 due to the presence of numerous regio-isomers.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Terpenos / Espectrometria de Massas em Tandem Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Terpenos / Espectrometria de Massas em Tandem Idioma: En Ano de publicação: 2024 Tipo de documento: Article