Your browser doesn't support javascript.
loading
Three robust Cd(II) coordination polymers as bifunctional luminescent probes for efficient detection of pefloxacin and Cr2O72- in water.
Fan, Xiao-Fei; Fu, Lianshe; Cui, Guang-Hua.
Afiliação
  • Fan XF; College of Chemical Engineering, Hebei Key Laboratory for Environment Photocatalytic and Electrocatalytic Materials, North China University of Science and Technology, No. 21 Bohai Road, Caofeidian new-city, Tangshan, Hebei, 063210, P. R. China. tscghua@126.com.
  • Fu L; Department of Physics and CICECO-Aveiro Institute of Materials, University of Aveiro, 3810-193 Aveiro, Portugal.
  • Cui GH; College of Chemical Engineering, Hebei Key Laboratory for Environment Photocatalytic and Electrocatalytic Materials, North China University of Science and Technology, No. 21 Bohai Road, Caofeidian new-city, Tangshan, Hebei, 063210, P. R. China. tscghua@126.com.
Dalton Trans ; 53(11): 5051-5063, 2024 Mar 12.
Article em En | MEDLINE | ID: mdl-38375864
ABSTRACT
The accurate and rapid detection of antibiotics and heavy-metal-based toxic oxo-anions in water media employing coordination polymers (CPs) as luminescent probes has attracted a lot of attention. Three new Cd(II)-based ternary CPs derived from first-presented L ligands, including [Cd(DCTP)(L)(OH)]n (1), [Cd(TBTA)(L)(OH)]n (2), and [Cd(NPHT)(L)(H2O)]n (3) (L = 2-((1H-imidazol-1-yl)methyl)-5,6-dimethyl-1H-benzo[d]imidazole, H2DCTP = 2,5-dichloroterephthalic acid, H2TBTA = tetrabromoterephthalic acid and H2NPHT = 3-nitrophthalic acid), were successfully assembled and characterized. 1 and 2 show 2D hcb layers, which can be further extended into a 3D supramolecular framework via classic hydrogen bonding interactions. 3 features a 1D double chain that ultimately spreads into a 2D network through weak hydrogen bonding interactions. With the advantages of high stability and excellent luminescent properties, the three CPs display high sensitivity, selectivity, and good anti-interference for the sensing of pefloxacin (PEF) and Cr2O72- ions (LOD values toward PEF 3.82 × 10-7 mol L-1 for 1, 4.06 × 10-7 mol L-1 for 2, and 1.36 × 10-8 mol L-1 for 3, and toward Cr2O72- ions 5.97 × 10-7 mol L-1 for 1, 5.87 × 10-7 mol L-1 for 2, and 8.21 × 10-8 mol L-1 for 3). These CPs are the first examples of bifunctional luminescent sensors to detect PEF and Cr2O72- in aqueous solutions. The luminescence quenching mechanisms are explored in detail.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article