Your browser doesn't support javascript.
loading
A tissue-silicone integrated simulator for right ventricular pulsatile circulation with severe functional tricuspid regurgitation.
Takada, Jumpei; Morimura, Hayato; Hamada, Kohei; Okamoto, Yusei; Mineta, Shiho; Tsuboko, Yusuke; Hattori, Kaoru; Iwasaki, Kiyotaka.
Afiliação
  • Takada J; Department of Modern Mechanical Engineering, School of Creative Science and Engineering, Waseda University, Tokyo, Japan.
  • Morimura H; Department of Integrative Bioscience and Biomedical Engineering, Graduate School of Advanced Science and Engineering, Waseda University, Tokyo, Japan.
  • Hamada K; Cooperative Major in Advanced Biomedical Sciences, Joint Graduate School of Tokyo Women's Medical University and Waseda University, Waseda University, Tokyo, Japan.
  • Okamoto Y; Waseda Research Institute for Science and Engineering, Waseda University, Tokyo, Japan.
  • Mineta S; Department of Integrative Bioscience and Biomedical Engineering, Graduate School of Advanced Science and Engineering, Waseda University, Tokyo, Japan.
  • Tsuboko Y; Department of Modern Mechanical Engineering, Graduate School of Creative Science and Engineering, Waseda University, Tokyo, Japan.
  • Hattori K; Department of Integrative Bioscience and Biomedical Engineering, Graduate School of Advanced Science and Engineering, Waseda University, Tokyo, Japan.
  • Iwasaki K; Waseda Research Institute for Science and Engineering, Waseda University, Tokyo, Japan.
Sci Rep ; 14(1): 5120, 2024 03 01.
Article em En | MEDLINE | ID: mdl-38429438
ABSTRACT
There is a great demand for development of a functional tricuspid regurgitation (FTR) model for accelerating development and preclinical study of tricuspid interventional repair devices. This study aimed to develop a severe FTR model by creating a tissue-silicone integrated right ventricular pulsatile circulatory simulator. The simulator incorporates the porcine tricuspid annulus, valve leaflets, chordae tendineae, papillary muscles, and right ventricular wall as one continuous piece of tissue, thereby preserving essential anatomical relationships of the tricuspid valve (TV) complex. We dilated the TV annulus with collagenolytic enzymes under applying stepwise dilation, and successfully achieved a severe FTR model with a regurgitant volume of 45 ± 9 mL/beat and a flow jet area of 15.8 ± 2.3 cm2 (n = 6). Compared to a normal model, the severe FTR model exhibited a larger annular circumference (133.1 ± 8.2 mm vs. 115.7 ± 5.5 mm; p = 0.009) and lower coaptation height (6.6 ± 1.0 mm vs. 17.7 ± 1.3 mm; p = 0.003). Following the De-Vega annular augmentation procedure to the severe FTR model, a significant reduction in regurgitant volume and flow jet area were observed. This severe FTR model may open new avenues for the development and evaluation of transcatheter TV devices.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Insuficiência da Valva Tricúspide Limite: Animals Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Insuficiência da Valva Tricúspide Limite: Animals Idioma: En Ano de publicação: 2024 Tipo de documento: Article