Your browser doesn't support javascript.
loading
Development of a flow injection chemiluminescence immunoassay based on DES-mediated CuCo2O4 nanoenzyme for ultrasensitive detection of zearalenone in foods.
Zeng, Xinziwei; Li, Jiao; Xu, Lingyun; Deng, Anping; Li, Jianguo.
Afiliação
  • Zeng X; The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Suzhou, 215123, People's Republic of China.
  • Li J; The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Suzhou, 215123, People's Republic of China.
  • Xu L; Analysis and Testing Center, Soochow University, Suzhou, 215123, People's Republic of China. lyxu@suda.edu.cn.
  • Deng A; The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Suzhou, 215123, People's Republic of China. denganping@suda.edu.cn.
  • Li J; The Key Lab of Health Chemistry & Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering & Materials Science, Soochow University, Suzhou, 215123, People's Republic of China. lijgsd@suda.edu.cn.
Mikrochim Acta ; 191(4): 175, 2024 03 04.
Article em En | MEDLINE | ID: mdl-38436786
ABSTRACT
Nanoenzymes have been widely used to construct biosensors because of their cost-effectiveness, high stability, and easy modification. At the same time, the discovery of deep eutectic solvents (DES) was a great breakthrough in green chemistry, and their combination with different materials can improve the sensing performance of biosensors. In this work, we report an immunosensor using CuCo2O4 nanoenzyme combined with flow injection chemiluminescence immunoassay for the automated detection of zearalenone (ZEN). The immunosensor exhibited excellent sensing performance. Under the optimal conditions, the detection range of ZEN was 0.0001-100 ng mL-1, and the limit of detection (LOD) was 0.076 pg mL-1 (S/N = 3). In addition, the immunosensor showed excellent stability with a relative standard deviation (RSD) of 2.65% for  15 repetitive  injections. The method has been successfully applied to the analysis of real samples with satisfactory recovery results, and can hence provide a reference for the detection of small molecules in food and feed.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Zearalenona / Técnicas Biossensoriais Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Zearalenona / Técnicas Biossensoriais Idioma: En Ano de publicação: 2024 Tipo de documento: Article