Capillary electrophoresis using triple layer modified capillary facilitating salivary ion analyses: Application to search for potential stress markers induced by cold pressure test.
Myochin, Hironori; Ohshima, Noriyasu; Izumi, Takashi; Hisajima, Tatsuya; Chaleckis, Romanas; Mori, Masanobu.
Afiliação
  • Myochin H; Department of Chemistry and Life Science, Faculty of Science and Technology, Kochi University, 2-5-1, Akebono-cho, Kochi 780-8520, Japan.
  • Ohshima N; Department of Biochemistry, Graduate School of Medicine, Gunma University, Maebashi, Gunma 371-8511, Japan.
  • Izumi T; Department of Biochemistry, Graduate School of Medicine, Gunma University, Maebashi, Gunma 371-8511, Japan; Faculty of Health Care, Teikyo Heisei University, 2-51-4, Higashiikebukuro, Toshima-ku, Tokyo 170-8445, Japan.
  • Hisajima T; Faculty of Health Care, Teikyo Heisei University, 2-51-4, Higashiikebukuro, Toshima-ku, Tokyo 170-8445, Japan.
  • Chaleckis R; Graduate School of Medical Sciences, Nagoya City University, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya 467-8601, Japan.
  • Mori M; Department of Chemistry and Life Science, Faculty of Science and Technology, Kochi University, 2-5-1, Akebono-cho, Kochi 780-8520, Japan. Electronic address: mori@kochi-u.ac.jp.
J Chromatogr A ; 1720: 464769, 2024 Apr 12.
Article em En | MEDLINE | ID: mdl-38442499
ABSTRACT
In this study, we introduce a novel approach for the analysis of salivary ions using capillary electrophoresis (CE) with a triple-layer coated capillary. The capillary is sequentially coated with cationic silylating reagents, poly(vinylsulfonate), and polybrene to form a custom designed surface that effectively inhibits adsorption of protein matrix on the capillary inner wall and allows for reproducible ion analysis. For the CE with capacitively coupled contactless conductivity detection, we used suitable background electrolytes (BGEs) for salivary ion analysis. Anions were separated using a mixture of 2-(N-morpholino)ethanesulfonic acid and l-arginine, and cations were separated using that with 18-crown-6. This setup enabled rapid separation, within 4 min, together with sensitive detection. We quantified nine common anions and five cations typically found in saliva samples using this CE method, both before and after a cold pressure test (CPT, a standard stress test). The CE system demonstrated consistent ion separation across 30 consecutive measurements without requiring capillary replacement. Notably, the salivary ion balance remained predominantly anion-rich, regardless of the CPT. Cold water exposure induced greater variation in the total anion concentration than in the total cation concentration. Further analysis using multiple regression analysis revealed strong relationships between nitrate and nitrite, formate and phosphate, and potassium and nitrate, before and after the CPT. Notably, potassium and nitrate ions exhibited variations in response to stress. These results provided a method for assessing salivary ion composition and insights into the potential of salivary ions as biomarkers for stress.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletroforese Capilar / Nitratos Idioma: En Ano de publicação: 2024 Tipo de documento: Article